Télécharger Imprimer la page

Endress+Hauser prosonic FMU 860 Mode D'emploi page 108

Masquer les pouces Voir aussi pour prosonic FMU 860:

Publicité

11 : Interface PROFIBUS-DP
Gestion d'appareil
Analog Input Block AI1
108
Paramètre
E+H-Parameter
TBAux Relay selection
TBAux Relay funktion
TBAux Switch-on point
TBAux Switch-off point
TBAux Alternating pump control
TBAux Count factor C1
TBAux Count factor C2
TBAux Count factor C3
TBAux Internal time
TBAux Switch delay
TBAux Operating mode
TBAux Select current
TBAux 4 mA threshold
TBAux Select distance unit
TBAux Flow unit
TBAux Counter unit
TBAux Limit switch
TBAux External temperatur sensor
TBAux Internal counter high
TBAux Internal counter low
TBAux Reset counter
TBAux Simulation level
TBAux Simulation volume
TBAux Simulation current
TBAux View1
Paramètre
Directory objekt header
Composite list directory entries
L'Analog Input Block AI1 contient la valeur mesurée de la première voie et est relié au
Transducer block TB1. Il comprend les paramètres suivants :
Paramètre
Standardparameter
Analog input block 1 block objekt
AI1 Static revision
AI1 Device tag
AI1 Strategy
AI1 Alert key
AI1 Target Mode
AI1 Mode block
AI1 Alarm summary
Blockparameter
AI1 OUT
AI1 PV_SCALE
AI1 OUT_SCALE
AI1 LIN_TYPE
AI1 CHANNEL
AI1 PV_FTIME
AI1 ALARM_HYSTERESIS
AI1 HI_HI_LIMIT
AI1 HI_LIMIT
AI1 LO_LIMIT
AI1 LO_LO_LIMIT
AI1 HI_HI_ALM
AI1 HI_ALM
AI1 LO_ALM
AI1 LO_LO_ALM
AI1 SIMULATE
AI1 OUT_UNIT_TEXT
AI1 View1
Matrice E+H
Slot
Index
Taille
(CW II)
V1H0
0
128
1
V1H1
0
129
1
V1H2
0
130
4
V1H3
0
131
4
V1H4
0
132
1
V1H5
0
133
4
V1H6
0
134
4
V1H7
0
135
4
V1H8
0
136
2
V1H9
0
137
1
V8H0
0
138
1
V8H1
0
139
1
V8H2
0
140
1
V8H3
0
141
1
V8H4
0
142
1
V8H5
0
143
1
V8H6
0
144
1
V8H7
0
145
1
V8H8
0
146
2
V8H9
0
147
2
V9H4
0
148
2
V9H7
0
149
4
V9H8
0
150
4
V9H9
0
151
4
0
152
13
Matrice E+H
Slot
Index
Taille
(CW II)
1
0
12
1
1
24
Matrice E+H
Slot
Index
Taille
(CW II)
1
16
20
1
17
2
1
18
32
1
19
2
1
20
1
1
21
1
1
22
3
1
23
8
1
26
5
1
27
8
1
28
11
1
29
1
1
30
2
1
32
4
1
35
4
1
37
4
1
39
4
1
41
4
1
42
4
1
46
16
1
47
16
1
48
16
1
49
16
1
50
6
1
51
16
1
61
13
Prosonic FMU 860...862
Taille
Read
Write
Storage
[bytes]
class
unsigned8
x
x
S
unsigned8
x
x
S
floating point
x
x
S
floating point
x
x
S
unsigned8
x
x
S
floating point
x
x
S
floating point
x
x
S
floating point
x
x
S
unsigned16
x
x
S
unsigned8
x
x
S
unsigned8
x
x
S
unsigned8
x
x
S
unsigned8
x
x
S
unsigned8
x
x
S
unsigned8
x
x
S
unsigned8
x
x
S
unsigned8
x
x
S
unsigned8
x
x
S
unsigned16
x
S
unsigned16
x
S
unsigned16
x
x
D
floating point
x
x
S
floating point
x
x
S
floating point
x
x
S
OSTRING
x
D
Taille
Read
Write
Storage
[bytes]
class
OSTRING
x
C
OSTRING
x
C
Taille
Read
Write
Storage
[bytes]
class
DS32*
x
C
unsigned16
x
N
Octet String(32)
x
x
S
unsigned16
x
x
S
unsigned8
x
x
S
unsigned8
x
x
S
DS37*
x
D
DS42*
x
D
DS33*
x
D
floating point(2)
x
x
S
DS36*
x
x
S
unsigned8
x
x
S
unsigned16
x
x
S
floating point
x
x
S
floating point
x
x
S
floating point
x
x
S
floating point
x
x
S
floating point
x
x
S
floating point
x
x
S
DS39*
x
D
DS39*
x
D
DS39*
x
D
DS39*
x
D
DS50*
x
x
S
Octet String(16)
x
x
S
OSTRING
x
D
Endress+Hauser

Publicité

loading

Ce manuel est également adapté pour:

Prosonic fmu 862