Télécharger Imprimer la page

Garant GRIDLINE 922001 Instructions D'utilisation page 22

Publicité

GARANT Vario workbench
de
6.2.
SUPPORT LEG
A
1. Secure each support leg to the worktop using three Ø8.4 washers and Ø8×32
woodscrews, using the pre-drilled holes.
bg
2. For workbenches without a casing standing on the floor: Repeat for the second
support leg.
6.3.
STABILISING PLATE
da
6.3.1.
Use cage nuts
B
i
For each stabilising plate, install two cage nuts at the head end of the leg in the
en
punched holes.
1. Insert the cage nuts into the punched recess obliquely from the front.
2. Use a screwdriver to push them back and clip them securely into position.
6.3.2.
Installing a single stabilising plate
fi
C
Does not need to be installed if installing the rear panel or installing the drawer
casing.
fr
1. Secure the stabilising plate using two M6×12 hex screws and cage nuts.
2. Secure the stabilising plate to the worktop using two Ø8.4 washers and Ø8×32
wood screws.
7.
Installing the rear panel and storage shelf
it
i
When installed as a rear panel, no stabilising plate is necessary.
7.1.
SCOPE OF SUPPLY
hr
Single-piece
1 pc. rear panel / storage shelf
4 pcs. M6 hex screw
4 pcs. cage nut
lt
Two-piece
2 pcs. rear panel / storage shelf
nl
8 pcs. M6 hex screw
8 pcs. cage nut
7.2.
USE CAGE NUTS
B
no
i
For each rear panel: At the top end or foot end of each support leg, install two
cage nuts on the inside punched recess.
For each storage shelf: At the lower cross brace of each support leg, install two cage
pl
nuts on the inside punched recess.
1. Insert the cage nuts into the punched recess obliquely from the front.
2. Use a screwdriver to push them back and clip them securely into position.
7.3.
REAR PANEL / STORAGE SHELF
pt
D
E
/
i
Install the rear panel at the rear of the workbench.
ro
Install the storage shelf in lower cross brace of each support leg.
During installation, leave the punched recesses for the cable ducts clear.
Secure the rear panel/support shelf to each support foot with two M6 hex-head
screws with cage nuts.
sv
8.
Installing the casing
i
Casing for installation on the left side or right side.
8.1.
SCOPE OF SUPPLY
sk
1 pc. casing
4 pcs. hex wood screw Ø 8 x 32 mm
4 pcs. washer
2 pcs. M6 x 10 round-head screw
sl
2 pcs. cage nut
8.2.
REMOVING THE DRAWERS
F
es
1. Pull out the drawer.
2. Pull out the locking mechanism and swing it upwards. Remove the drawer.
8.3.
USE CAGE NUTS
B
cs
i
Applies only to a suspended casing. Fit two cage nuts at the head end of the front
leg into the punched holes on the inside.
1. Insert the cage nuts into the punched recess obliquely from the front.
hu
2. Use a screwdriver to push them back and clip them securely into position.
22
8.4.
INSTALLING THE CASING
G
H
/
i
Two persons working together turn the worktop over and place it on a flat and
clean support surface.
Install the casing on the worktop according to the hole pattern.
1. Remove the drawers (see Removing the drawers) or open the door.
2. Only for casing size 200 to 500: Screw M6×10 mm raised-head self-tapping
screws into the cage nuts in the support leg.
3. Screw the casing to the worktop using four washers and four Ø 8×32 mm hex
screws.
8.5.
INSERTING THE DRAWERS
I
1. Pull out the pull-out rails and secure them.
2. Insert the drawer and push it in until you sense resistance.
3. Lift the drawer up and push it over the resistance until it is fully inserted on the
rails.
4. Swing the locking mechanism down and push it to the back.
9.
Setting up the workbench
9.1.
SET-UP
ü At least 2 persons must be employed to transport the workbench to the set-up
location.
ü Ensure there is a solid, level floor suitable for the maximum load capacity of the
workbench.
1. Set up the workbench on a level and solid floor.
2. Use a spirit level to check whether the workbench is horizontal and perpendicu-
lar.
»
Position the workbench in the set-up location.
9.2.
ANCHORING
WARNING
Workbench tipping over
Risk of injury
Risk of tipping over, when workbench weighs <150 kg and the loading per drawer is
>35 kg.
»
Anchor the workbench to the floor.
NOTICE
Wiring and pipes installed in the floor
Damage to wiring and pipes.
»
Check floor for sufficient load-bearing capacity before drilling.
»
Use suitable drill and drilling materials.
»
Use suitable protective equipment.
»
Drilling to be carried out by trained personnel.
»
Do not drill in the immediate vicinity of wiring or pipes.
10. Storage
Storage temperature between -10°C and +60°C.
Store in an enclosed dry room.
Atmospheric humidity: 90 %, non-condensing.
11. Maintenance
Do not use alcoholic, abrasive or solvent-based cleaning agents.
Interval
Maintenance work
Before each occa-
Check workbench for external damage.
sion of use
Monthly
Check all components and screw fasten-
ings on the workbench for tightness and
operation.
Remove external dust and dirt.
Check for damage and cracks.
If the workbench is
Clean the side panels, metal fronts,
dirty
drawers and feet with paint cleaner.
Clean the worktop with a damp cloth.
In the event of
Block access to the workbench and pre-
damage to the
vent its use.
workbench, com-
Have damaged components and ac-
ponents and ac-
cessories replaced immediately.
cessories
12. Spare parts
Order original spare parts from the Hoffmann Group Customer Service.
13. Technical data
i
The technical data for the accessories can be found in the relevant manual for the
accessories.
Dimensions
Performed by
Trained person
Trained person
Trained person
Trained specialist for
mechanical work