reduced.
Using the securing cable
When installing, never hang the equipment by the
discharge line or by the power cable. The equip-
ment must be hung from the suspension eyelets
provided or it must rest on the bottom of the shaft.
To ensure that the equipment works properly, the
bottom of the shaft must always be free of sludge
and other accumulations of dirt. If the water level
is too low, the sludge in the shaft can quickly dry
out and hinder the equipment from starting. It is
necessary therefore to check the equipment regu-
larly (carry out trial start-ups).
Installing the pump:
Avoid intake of sediment and solid matter (e.g.
sludge, sand, etc.), which can cause damage to
the pump. Make sure there is suffi cient distance
between the pump and the ground, and clean the
pump shaft regularly, as needed. Assemble or
remove the pedestal, depending on the intended
use of the pump.
The pump shaft should be large enough.
Operating the pump without the pedestal
(Figure 3):
If the pump is to be used in a deep well or in a
narrow shaft with a minimum diameter of 100 mm,
the pedestal must be removed from the pump
(Figure 2). Undo the corresponding screws on the
pump.
Attach the securing cable to the deep well pump
and lower it into the well or shaft. To ensure that it
is safely positioned, fi rst let the pump drop to the
bottom. Then pull back on the taut cable and se-
cure the pump at the defi ned distance. The pump
must not be placed on the ground.
Operating the pump with the pedestal
(Figure 4 +5)
If the pump is to be resting on the ground (e.g.
when used in a cistern), attach the pedestal to the
pump with the corresponding screws (Figure 2).
This ensures that the pump will remain at a defi -
ned distance from the ground, reducing the intake
of sediment and solid matter. Always secure the
pump with the securing cable and make sure the
cable is taut so that the pump does not fall over.
Anl_GC_DW_1045_N_SPK13.indb 13
Anl_GC_DW_1045_N_SPK13.indb 13
GB
5.2 Mains connection
Danger!
The equipment you have purchased comes with
an earthing-pin plug. The equipment is designed
for connection to a socket outlet with earthing
contact for 220-240 V ~ 50 Hz. Make sure that the
socket-outlet is suffi ciently fused (at least 6 A)
and in good working order. Insert the power plug
in the socket-outlet and the equipment is ready
for operation.
6. Operation
You can put the equipment into operation after
you have thoroughly read the installation and ope-
rating instructions. Pay attention to the following
points:
•
Check that the discharge line is fitted correct-
ly.
•
Make sure that the electrical connection is
220-240 V ~ 50 Hz.
•
Check that the electrical socket-outlet is in
good working order.
•
Make sure that no moisture or water can ever
reach the power connection.
•
Lower the pump into the well or shaft using
the securing cable.
•
Ensure that the pump is completely sub-
mersed in the water and that there is suffici-
ent distance between the pump intake section
and the ground.
•
Make sure that the equipment does not run
dry.
•
To switch off the equipment, pull the power
plug out of the socket outlet.
7. Replacing the power cable
Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.