Error/Fault
If you can't fix the fault yourself, contact your nearest
vendor. Please be aware that any improper repairs
will also invalidate the warranty and additional costs
may be incurred.
Disposal
Disposal of the appliance
A crossed-out wheelie bin icon means: Bat-
teries and rechargeable batteries, electrical
or electronic devices must not be disposed of
with household waste. They may contain
substances that are harmful to the environ-
ment and human health.
Consumers must dispose of waste electrical devices,
spent portable batteries and rechargeable batteries
separately from household waste at an official collec-
tion point to ensure that these items are processed
correctly. The product can be returned free of charge
in accordance with the legal requirements, for exam-
ple through a municipal waste disposal company or a
dealer.
Batteries, rechargeable batteries and lamps
that are not permanently installed in waste
electrical equipment and can be removed in
a non-destructive way must be removed and
disposed of separately before disposal of the equip-
ment. Lithium batteries and rechargeable battery
packs of all systems are only to be handed in to the
waste collection points in a discharged state. The bat-
teries must always be protected against short circuits
by taping off the poles.
All end users are responsible for deleting any per-
sonal data stored on waste devices prior to their dis-
posal.
Disposal of the packaging
The packaging consists of cardboard and
correspondingly marked plastics that can
be recycled.
– Make these materials available for recy-
cling.
Technical data
Item number
Model
Nominal voltage
Nominal output
Protection type
Characteristic curve
Max. conveying level
Max. suction level
Cause
Pump is blocked or defective?
Air in the pump or suction pipe?
Changed suction conditions in
spring (springs e. g. covered in
sand)?
Suction pipe sucked in on the
ground?
309744
GP 6000
230 V~, 50 Hz
900 W
IPX4
► P. 4, fig. 2
44 m
8 m
Remedy
Clean the pump with clean water
and remove the cause of the con-
tamination.
Fill pump case with water.
For suction pipes with check valve,
fill suction pipe with water.
Check spring and water quality.
Shorten or fasten suction pipe.
Use filter screen with check valve.
Item number
Max. conveying amount
Max. fluid temperature
Diameter of pressure line
Diameter of suction line
Accessories
Accessories are available from your local vendor.
GB
309744
6000 l/h
35 °C
25 mm (1")
25 mm (1")
27