Features & Controls
Electronic Touch
1. POWER BUTTON
►
The POWER button will turn the power on and off for the entire hood (fan and lights). The hood
has a memory function and will remember the last speed and light level it was turned off at.
DELAY OFF FUNCTION: With the fan on, press and hold the POWER button for 2 seconds. The fan
will change to speed 1 and the POWER button will blink on and off, indicating the delay off timer
has started. After 5 minutes, the hood will power off. Pressing the POWER button while the delay
off function is enabled will turn off the hood and cancel the delay off function.
ACT™ VERIFICATION: Airflow Control Technology (ACT™) allows the installer to set the maximum
blower CFM to align with local codes and regulations.
►
To verify the maximum fan CFM, press and hold the POWER button for 5 seconds while the
entire hood is powered off. If all three fan speed indicators illuminate = default maximum
CFM. If two fan speed indicators illuminate = 390 maximum CFM. If one fan speed indicators
illuminate = 290 maximum CFM.
2. FAN 1 - FAN 3 BUTTONS
►
There are three fan speed levels. 1 for low speed, 2 for medium speed, and 3 for high speed.
3. LIGHTS BUTTON
►
There are two light levels, low and high.
►
From off, press once for low, and press twice for high. Press again to power off the lights.
18
BMI-D & BVE-C Use, Care, and Installation Guide
B R I S A S
B M I & B V E
WA L L