The admin code is max 6 digits.
3. Once you have access, the yellow LED will
come on.
On the ACMR-P model, the
replaces .
Access mode setting
After going into programming:
Press buttons
and
flash yellow.
Choose one of the following modes:
For access with card only, press button
For access either with card or code, press buttons
and .
For access with combined use of card and code, press
buttons
and .
The status indicator will turn solid yellow and a
long beep will sound to confirm the device has
been programmed.
Press button
to exit programming mode.
Setting the length of the password
After going into programming:
Press buttons
and
flash yellow.
Press buttons
; there will be a warning "Beep",
then enter X, where X represents the number of
digits that make up the password (X=2,3,4,5,6):
There will be another sound to indicate that the
digit length setting was successful.
If there are 3 consecutive sounds, this means the
length is the same as the existing one, and the new
setting is not permitted.
Press button
to exit programming mode.
Once the length of the password has been
changed, all the access cards and codes previ-
ously entered will be cleared.
button
; the LED indicator will
twice.
, the LED indicator will
Adding a user card and code (ZONE 1)
After going into programming:
1. Enter 3 digits from 000 to 999 to identify the data
storage unit; a yellow LED indicator will flash:
2. If the LED indicator is red, it means that data
is already stored in the unit. Press button
twice to clean up and start again from point 1.
3. If the LED indicator is green, it means that
access cards and codes can be added to the
data storage unit.
Adding access cards and codes
4. Swipe the card; the sound indicates that it has
been added. Key in the relative access code. The
length of the access code should be the same as
the admin code. For example, if the admin code
is 12, you can set 00-99 as your password. The
sound indicates that the access card and code
have been added correctly.
Press button
to exit programming mode.
Deleting a user card and code (ZONE 1)
After going into programming:
Enter 3 digits from 000 to 999 to identify the data
storage unit; if the red LED is on, this means there
is data stored in this unit. Press button
delete the card and code of this data storage unit.
Modifying the user code in ZONE 1
After going into programming:
Press buttons
and . The LED indicator will flash
yellow. Press buttons
enter three digits from 000 to 999 to identify the
data storage unit to modify and enter the related
passwords (the length of the access code must be
the same as the admin code).
Press button
to exit programming mode.
twice to
and
. After the beep,