4. Technical data
Voltage ...................................................36 V d.c.
Idling speed n ........................ 10,00-25,200 rpm
Air speed max. ......................................230 km/h
Air volume max. .................................... 890 m³/h
Sound pressure level L
Uncertainty K
............................................ 3 dB
pA
Measured sound power level L
K
uncertainty ....................................... 0.58 dB
WA
Guaranteed sound power level L
Vibration a
.......................................... ≤ 2.5 m/s²
h
Uncertainty K ......................................... 1.5 m/s²
Weight ....................................................... 2.5 kg
Important!
The equipment is supplied without batteries and
without a charger and is allowed to be used only
with the lithium-ion batteries of the Power X-
Change series!
The lithium-ion batteries of the Power X-Change
series are allowed to be charged only with the
Power-X charger.
Measured and guaranteed sound power level
determined in accordance with 2000/14/EC,
extended by 2005/88/EC.
The value given for vibration was determined in
accordance with a set of standardized criteria and
can be used to compare diff erent products with
one another. This value is also suitable to be used
for estimating the strain on the user caused by the
vibration beforehand.
Caution!
Depending on how you use the device, the actual
vibration emissions can vary from the values lis-
ted above. Take appropriate measures to protect
yourself against vibration stress. Take the entire
work sequence into consideration including times
at which the device is not working under load or
is switched off . Appropriate measures include
among other things regular care and maintenance
of the device and tool attachments, keeping your
hands warm, taking regular breaks and good
work sequence planning.
Anl_GP_LB_36_230_Li_E_BL_SPK13.indb 14
Anl_GP_LB_36_230_Li_E_BL_SPK13.indb 14
................... 84.5 dB (A)
pA
.... 93.28 dB(A)
WA
....... 94 dB(A)
WA
- 14 -
GB
Keep the noise emissions and vibrations to a
minimum.
•
Only use appliances which are in perfect wor-
king order.
•
Service and clean the appliance regularly.
•
Adapt your working style to suit the appliance.
•
Do not overload the appliance.
•
Have the appliance serviced whenever ne-
cessary.
•
Switch the appliance off when it is not in use.
•
Wear protective gloves.
•
Wear ear-muffs.
Caution!
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain resi-
dual risks cannot be rules out. The following
hazards may arise in connection with the
equipment's construction and layout:
1. Lung damage if no suitable protective dust
mask is used.
2. Damage to hearing if no suitable ear protec-
tion is used.
3. Health damage caused by hand-arm vib-
rations if the equipment is used over a pro-
longed period or is not properly guided and
maintained.
4. Risk of eye damage if suitable safety goggles
are not worn.
5. Before starting the equipment
Important!
The machine is supplied without batteries and
without a charger!
Warning!
Always remove the battery pack before making
adjustments to the equipment.
5.1 Fitting the blower tube (Fig. 3a/b)
There are three settings for adjusting the length of
the blower tube to your requirements.
Plug the blower tube onto the motor unit. The
groove (A) must be pushed into the guide (B)
when you do this. Turn the blower tube to the right
to secure it in its fi nal position on the motor unit.
Caution! The tube must be turned as far as
it will go to make sure it is fi rmly secured in
position.
24.10.2024 08:27:18
24.10.2024 08:27:18