3. Trimmer
Screw size
M10 × 1.5
M8 × 1.25
M6 × 1
W3/8" × 1.5875
Optional accessories are subject to change without notice.
APPLICATIONS
○ Cutting of soft steel studs.
BATTERY REMOVAL/INSTALLATION
1. Battery removal
Hold the handle tightly and push the battery latch to
remove the battery (see Figs. 1 and 2).
CAUTION
Never short-circuit the battery.
2. Battery installation
Insert the battery while observing its polarities (see
Fig. 2).
Before
charging
While
charging
Charging
The pilot
complete
lamp lights
or blinks.
Charging
impossible
Overheat
standby
(2) Regarding the temperatures and charging time of the battery.
The temperatures and charging time will become as shown in Table 2
Type of battery
Temperatures at which the
battery can be recharged
Charging voltage
Battery
Charging time,
approx. (At 20°C)
NOTE
The charging time may vary according to temperature and power source voltage.
Indications of the pilot lamp
Lights for 0.5 seconds. Does not light for
Blinks
0.5 seconds. (off for 0.5 seconds)
(red)
Lights continuously
Lights
(red)
Lights for 0.5 seconds. Does not light for
Blinks
0.5 seconds. (off for 0.5 seconds)
(red)
Lights for 0.1 seconds. Does not light for
Flickers
0.1 seconds. (off for 0.1 seconds)
(red)
Lights for 1 seconds. Does not light for
Blinks
0.5 seconds. (off for 0.5 seconds)
(red)
Charger
V
14.4
BSL14xx series
(8 cells)
BSL1430 : 45
BSL1440 : 60
min.
BSL1450 : 75
BSL1460 : 90
CHARGING
Before using the power tool, charge the battery as follows.
1. Connect the charger's power cord to a receptacle.
When the power cord is connected, the charger's pilot
lamp will blink in red. (At 1-second intervals)
2. Insert the battery into the charger.
Firmly insert the battery into the charger, as shown in
Fig. 3.
3. Charging
When inserting a battery in the charger, charging will
commence and the pilot lamp will light continuously in
red.
When the battery becomes fully recharged, the pilot
lamp will blink in red. (At 1-second intervals) (See
Table 1)
(1) Pilot lamp indication
The indications of the pilot lamp will be as shown in
Table 1, according to the condition of the charger or the
rechargeable battery.
Table 1
Table 2
UC18YFSL
Li-ion
0°C – 50°C
BSL18xx series
(10 cells)
BSL1830 : 45
BSL1840 : 60
BSL1850 : 75
BSL1860 : 90
English
Malfunction in the battery or
the charger
Battery overheated.
Unable to charge.
(Charging will commence
when battery cools)
18
Multi volt series
(10 cells)
BSL36A18 : 75
BSL36B18 : 120
11