TFD-34TEV
Fau lt Code Information and Maintenance
NOTE: tampering with electronic must only be performed by trained personnel
only !
Note Troubleshooting: The Model TFD-34TEV is equipped with an electronic Diagnostics program
provided information of failure such as motor overload, high or low
voltage, etc.
Discovered on the machine when an error happened, it will stop automatically and the error is on
the LED display is shown. Follow the description below to solve the problem.
Press the start button (Reset) to start the engine again.
LED dis
Fault Name
Over current
Abnormal increase in current.
Over voltage
The DC bus voltage has exceeded
its maximum allowable value.
Overheating
Heat sink temperature too high
l p
y a
W
n i
d
o
w
s
Fault Descriptions
Corrective Actions
1. To check whether the voltage with the
motor and the electronic motor
controller match.
2. The cabling between the electronic
Motor controller and motor.
Check that the input voltage circuit with
the electronic governor match.
1. To make sure that the vents not
clogged.
2. Check that the heat sink free of debris
and dirt.
21