6. Maintenance:
Warning: Do not begin service before turn off the machine and remove the power plug from
the power source .
NR.
Machine parts
1
Column
2
Worktable
3
Worktable
Work table /
4
machine foot
5
Column
6
Panel
7
Power cable
8
Pump
9
Coolant
10
11
Machine foot
12
V-belt
13
Table elevation
15
Belt cover
16
Spindle
17
Toothed rack
Microswitch
18
Emergency stop switch
RECOMMENDED FOR USE: LUBRICANT ISO 68
Period
Every 10 days 1. Apply lubricant
Every 10 days
Every 10 days
Every 10 days
Every 10 days
Every 10 days
Every week
1. Use
Every 3 months
Motor
Every 3 months
Every day
Every week
Every week
Every week
Every day
Every week
Every day
Method
1. Removing chips and clean
2. Apply rustproofing
1. Avoid damage to the surface of the
worktable.
1. After running, the table must return to the
original position to avoid
deformations.
1. Column free of stains
2. Add lubricants to prevent rust
3. When damages on the surface was found
on column, fix this or replace the column.
1. Wipe off cutting fluid or oil stains
1. Check cable for damage
1. Check direction of flow
2. If it is running in the opposite direction,
the rotation must exchange through
corrected current phases (via specialist).
1. Check on fluid level and chemical reactions
observed.
1. Remove dust from the motor.
Keep the motor dry.
1. Apply cleanning and rust protection
1. For correct belt tension and check aging
1. Remove dust and chips, and then apply
lubricant
1. Make sure that the belt cover closes
properly.
1. Make sure the spindle can restore properly.
2. Apply lubricant
1. Remove dust and chips
2. Apply lubricant
1. Turn the switch on and off.
2. Replaced by a new one when the switch
is damaged or repair it immediately.
15