OPTIONAL CB36 BLOWER WIRING DIAGRAM
DANGER: SHOCK HAZARD DISCONNECT POWER SOURCE BEFORE
INSTALLATION AND WHENEVER SERVICING BLOWER ASSEMBLY.
WHITE /
BLANC
BLACK /
NOIR
BLOWER
RHEOSTAT /
RHÉOSTAT DU
VENTILATEUR
NOTICE: ANY REPLACEMENT WIRING MUST HAVE EQUIVALENT INSULATION AND TEMPERATURE RATING (105° C).
NOTICE: DO NOT ALLOW THE POWER CORD TO TOUCH HOT SURFACES! KEEP THE POWER CORD AT LEAST
INSTRUCTIONS SPECIFIC FOR CANADIAN
Do not obstruct the space under the heater and do not
obstruct the combustion air openings.
Refer to the chimney manufacturer's instructions for
disassembling the chimney for transportation of a
transportable building.
The parts or materials to be employed for ember protectors
and the minimum areas to be covered and their relation
to the space heater, as well as the notice: "In Canada, to
comply with CSA B365, Installation Code for Solid-Fuel-
Burning Appliances and Equipment, any combustible
covering beneath the appliance and/or within the area
extending horizontally at least 450 mm (18 in) beyond the
appliance on any side equipped with a door, and at least
200 mm (8 in) beyond the appliance on other sides, shall
be protected by a continuous, durable, non-combustible
pad that will provide ember protection. The 450 mm (18
© 2024 United States Stove Company
BLACK /
NOIR
BLACK /
NOIR
GREEN /
WHITE /
VERT
BLANC
12"/30.5CM FROM THE STOVE OR PIPE SURFACES.
INSTALLATIONS
CAUTION: MOVING PARTS CAN CAUSE
INJURY. DO NOT OPERATE WITH COVER
BLACK /
NOIR
BLACK /
NOIR
BLOWER SPECS: 120VAC, 60 Hz AC,0.55amp
MOTEUR DE VENTILATEUR
SPÉCIFICATIONS DU VENTILATEUR : 120 V CA,
in) ember protection required on any side with a door shall
extend for the full width of the appliance plus the 200 mm
(8 in) required on each side of the appliance without a
door. Where an appliance is installed less than 200 mm (8
in) from a wall, the ember pad need only extend to the base
of the wall. An ember pad shall not be placed on top of a
carpet unless the pad is structurally supported to prevent
displacement and distortion.
Note: Do not install the chimney directly at the outlet of
the appliance. A chimney connector (flue pipe) is required.
If this appliance is installed in a transportable building,
removal of the chimney is required for transportation of
the building.