Owner's Instruction and Operation Manual
Model Numbers:
VG2020E-P
VG2020E-BP • VG2020E-BL
VG2020E-W
Report Number: F19-476
Tested Per EPA M28R & ASTM E2515 and CSA B415 .1-10
Certified to UL 1482-2022, CAN/ULC S627:2023
Mobile home / transportable building approved
* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
SAFETY NOTICE: If this heater is not properly installed, a house fire may result. For
your safety, follow the installation instructions. Never use make-shift compromises
during the installation of this heater. Contact local building or fire officials about
permits, restrictions and installation requirements in your area. NEVER OPERATE THIS
PRODUCT WHILE UNATTENDED.
CAUTION! Please read this entire manual before you install or use your new room
heater. Failure to follow instructions may result in property damage, bodily injury, or
even death. Improper Installation Will Void Your Warranty!
U.S. Environmental Protection Agency
Certified to comply with 2020 particulate
emissions standards.
© 2024 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380
• VG2020E-L
R
Save These Instructions In A Safe Place For Future Reference.
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals
including carbon monoxide, which is known to the
State of California to cause cancer, birth defects,
and/or other reproductive harm. For more
information, go to
854110-1206N
www.P65warnings.ca.gov
Ph. 800-750-2723

Publicité

loading

Sommaire des Matières pour VOGELZANG VG2020E-P

  • Page 1 Owner’s Instruction and Operation Manual Model Numbers: VG2020E-P • VG2020E-L VG2020E-BP • VG2020E-BL VG2020E-W Report Number: F19-476 Tested Per EPA M28R & ASTM E2515 and CSA B415 .1-10 Certified to UL 1482-2022, CAN/ULC S627:2023 Mobile home / transportable building approved * All Pictures In This Manual Are For Illustrative Purposes Only.
  • Page 2 The instructions pertaining to the installation of your wood stove comply with UL1482-2022 and CAN/ULC S627:2023 standards. This manual describes the installation and operation of the Vogelzang, VG2020E-P, VG2020E-L, VG2020E-BP, VG2020E-BL, VG2020E-W wood heater. This heater meets the 2020 U.S. Environmental Protection Agency’s cribwood emission limits for wood heaters sold after May 15, 2020.
  • Page 3 INSTALLATION CHECKLIST Your Wood Stove should be installed by a qualified installer only. An NFI qualified Installer can be found at www.nficertified. org/public/find-an-nfi-pro/ CUSTOMER SERVICE 1-800-750-2723 ext 5050 Text to 423-301-5624 Email to: Customerservice@usstove.com COMMISSIONING CHECKLIST This Checklist is to be completed in full by the qualified person who installs this unit. Keep this page for future reference. Failure to install and commission according to the manufacturer’s instructions and complete this checklist will invalidate the warranty.
  • Page 4 ASSEMBLY INSTRUCTIONS FOR CUSTOMER SERVICE CALL: 800-750-2723 EXT 5050 TOOLS AND MATERIALS ASH PAN ASSEMBLY You will need a drill with a 1/8” bit to install sheet metal Remove ash pan from firebox. Under the firebox, there are screws into connector pipe. A 5/16” socket/wrench or two brackets;...
  • Page 5 ASSEMBLY INSTRUCTIONS FIREBRICK CONFIGURATION AIR DEFLECTOR ASSEMBLY Replace the Firebrick as shown in the illustration. Use the provided screws to attach the air deflector to the rear of the unit. INSTALLATION SAFETY NOTICE • IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT.
  • Page 6 INSTALLATION FLOOR PROTECTOR • A flue pipe crossing a combustible wall must have a minimum clearance of 18” (458 mm). This heater must have a non-combustible floor protector with an R-Value of at least 1.4 installed beneath it if the •...
  • Page 7 INSTALLATION SECURING APPLIANCE’S ON A PEDESTAL fireplaces or other heating appliances, smell, do TO THE FLOOR not operate properly, suffer smoke roll-out when opened, or back-drafts occur whether or not there is Use the designated holes to secure the unit to the floor. combustion present.
  • Page 8 INSTALLATION CHIMNEY case, we recommend you contact your dealer to ensure there will be no problem with the draft. The stovepipe must be made of aluminized or cold roll steel and have a minimum thickness of 0.021” or 0.53 mm. It is strictly forbidden to use galvanized steel.
  • Page 9 INSTALLATION FACTORY BUILT CHIMNEY When a metal prefabricated chimney is used, the Concrete Cap Fireclay Flue manufacturer’s installation instructions must be followed. Liner With Airspace 1” Clearance You must also purchase (from the same manufacturer) with Firestop and install the ceiling support package or wall pass- through and “T”...
  • Page 10 INSTALLATION METHOD B - 9” (228.6 mm) Clearance to Combustible Wall Member: Using a 6” (152.4 mm) inside diameter, listed, factory-built Solid-Pak chimney section with insulation of 1” (25.4 mm) or more, build a wall pass-through with a minimum 9” (228.6 mm) air space between the outer wall of the chimney length and wall combustibles.
  • Page 11 OPERATION INSTRUCTIONS NEVER OPERATE THIS PRODUCT WHILE UNATTENDED better energy yields than others. Higher efficiencies and CAUTIONS: HOUSE FIRE HAZARDS lower emissions generally result when burning air dried • DO NOT STORE WOOD ON FLOOR PROTECTOR, seasoned hardwoods, as compared to softwoods or too UNDERNEATH STOVEPIPE(S) ANYWHERE...
  • Page 12 OPERATION INSTRUCTIONS center then the wood should be dry enough to burn. If your vapor. The higher heating value is when water leaves the wood sizzles in the fire, even though the surface is dry, it combustion process completely condensed. In the case may not be fully cured and should be seasoned longer.
  • Page 13 OPERATION INSTRUCTIONS For a cold start-up, place 3 to 4 pieces of newspaper into 8 lbs the firebox. On top of the newspaper, lay 3 lbs of kindling in random placement to ensure airflow through the kindling. On top of the kindling, place approximately 4 lbs of small pieces of cordwood.
  • Page 14 OPERATION INSTRUCTIONS for faster speeds. To turn the blower off, turn the speed blower should be removed at the beginning of every “burn” control knob fully counter-clockwise. It is recommended season and air-blown clean, removing any dust or build-up. to turn the blower off when the unit is not in operation. The CHIMNEY MAINTENANCE NEVER OPERATE THIS PRODUCT WHILE UNATTENDED TO PREVENT CREOSOTE BUILD UP...
  • Page 15 CHIMNEY MAINTENANCE and replace the damaged piece with a new one. Perform CAUTIONS: the procedure backward after replacing it. When • ASHES COULD CONTAIN HOT EMBERS EVEN AFTER replacing the glass, you should change the glass gasket TWO DAYS WITHOUT OPERATING THE STOVE. to make sure you keep it sealed.
  • Page 16 OPTIONAL CB36 BLOWER WIRING DIAGRAM CAUTION: MOVING PARTS CAN CAUSE DANGER: SHOCK HAZARD DISCONNECT POWER SOURCE BEFORE INJURY. DO NOT OPERATE WITH COVER INSTALLATION AND WHENEVER SERVICING BLOWER ASSEMBLY. REMOVED. WHITE / BLACK / BLACK / BLANC NOIR NOIR BLACK / BLACK / BLACK / NOIR...
  • Page 17 REPAIR PARTS Part # Description 40292A 6” Flue Collar 88042 Rope Gasket 1/4” 25845 Air Deflector 891492 Blower Assembly (CB36) 26060 Rear Shield 610926 Rear Pedestal 29068 Pedestal 29065 Pedestal Front 610960 Pedestal Base Weldment 610925 Ashpan Housing 610883 Leg Weldment 25826 Hearth Plate 29071...
  • Page 18 REPAIR PARTS Part # Description 88375 Upper Baffle Board 88374 Main Baffle Board 894134 Rear Tube Assembly 894135 Middle Tube Assembly 894136 Front Tube Assembly 894127 Brick Retainer 23783 Firebrick (1-1/4 x 2-9/16 x 9) 27338 Firebrick (1.25” x 2.25” x 4.5”) 89066 Firebrick (4-1/2 x 9) 24103...
  • Page 19 SERVICE RECORD It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed. SERVICE PROVIDER Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the manufacturer’s instructions.