Télécharger Imprimer la page

CAME 806TF-0120 Mode D'emploi page 14

Publicité

D
Installation
1
Make a hole in the board box and thread the electrical cables through the hole using
the sealing gasket provided. Position the control board at the correct angle (0°-90°).
2
Slot the gasket and electronic board into the base in the desired position.
3
Secure the front cover using the screws and rubber plugs.
Connections and settings
Use FROR cables 4 x 0.5 mm and 3 x 0.5 mm.
E
Connecting a pair of photocells.
Connecting two pairs of photocells.
G
Connecting two pairs of photocells.
Set each pair of RX-TX photocells with its own address via the DIP switches
(1-2-3).
H I
Connecting multiple pairs of photocells (max. 8).
- Set each pair of RX-TX photocells with its own address via the DIP switches (1-2-3) and
connect the SY terminals on the TX photocells together.
In a pair of photocells, all DIP-switches must be set to OFF, as shown in RX1
and TX1.
- On the TX, use DIP-switch (4) for setting the obstacle recognition sensitivity.
OFF = maximum obstacle sensitivity (max. 4 pairs of photocells synchronised).
ON = normal sensitivity (5-8 pairs of photocells synchronised).
In mixed installations with other types of photocells, set the sensitivity lower
[DIP switch 4 ON] to prevent the photocells from interfering with one another.
F
If the services test function has been set on the CAME control panel, connect the TX
photocells to terminals 10 and TS, instead of 10 and 11, on the control panel.
For the OUT output contacts, always check the connection and function
instructions in the relevant CAME control panel manual.
For installations alongside photocells of a diff erent type, we recommend
installing TX transmitters and RX receivers alternately, as shown in the fi gure
E