Reprogramming Procedure
>3''
>3''
PROG
<6''
<6''
B
B
1
M1
2
1-2-3
1-2-3
+
5
12345
12345
+
6
<1''
<1''
PROG
B
B
7
M1
>3''
>3''
PROG
<6''
<6''
B
B
8
M1
9
Entering Programming Mode. Press the PROG key 1 for at least 3 seconds and
release within 6 seconds. If the PROG LED immediately goes out it means there is a
malfunction. Check the connections and return to programming. The LEDS on the entry
panels light up as shown in fi gure 2. Wait 5 seconds for the auto test to be completed
CN4
and continue as shown below.
3
Programming the call keys. Press the door release
the entry panel, press the call key to be linked to the receiver 4: a beep will confi rm
that the setting has been stored. Continue, repeating the same operations for all the
other receivers.
Programming the door release code and relay with DNA. Press
relay code you wish to programme (press key 1 to activate the door opening control in
the entry panel; press key 2 to activate relay 1 on the VLS/2 relay module; press key 3
beep
beep
+
Exiting Programming. Briefl y press the PROG key 7: the PROG LEDs and entry panel
LEDs will go out. If no action is performed, the procedure will end automatically after
30 minutes.
CN4
Programming Type of Keys. In "Programming Call Keys" 2 press the PROG key 8
and release it within 6 seconds to go into the "Programming Type of Keys" procedure I.
CN4
4
to activate relay 2 on the VLS/2 relay module) 5.
Press
once again and key in the desired code (from 3 to 5
fi gures). Once programming has been completed, by pressing the
key plus the desired code and
door opening control and relay 1 or 2 6.
beep
beep
and AUX2 buttons 3. On
and key in the
it is possible to activate the