Télécharger Imprimer la page

CAME DVC/01 Manuel De Programmation page 26

Publicité

1-2-3
1-2-3
+
7
12345
12345
+
8
Entering Codes and Tags
1
2
12345
12345
+
5
12345
12345
+
beep
beep
6
7
Programming the door release code and relay with DNA. Press
relay code you wish to programme (press key 1 to activate the door opening control in
the entry panel; press key 2 to activate relay 1 on the VLS/2 relay module; press key 3
to activate relay 2 on the VLS/2 relay module) 7. Press
desired code (from 3 to 5 fi gures).
beep
beep
+
Position the power supply's PROG RFID jumper at "+" 1: the power supply's PROG
LED will fl ash slowly along with the message LEDs with the confi guration in fi g. 2. If
the LEDs immediately go out it means there is a malfunction in the connections between
the power supply and entry panel. Check the connections and return to programming.
3
+
beep
beep
Codes. Press
, enter the access code (4-8 fi gures) followed by the
keypad of any already addressed entry panel reader 5 and, after the confi rmation beep,
enter the call code for the group and then press
the maximum permitted number is exceeded (5) for each group, an error tone will be
generated.
Finally, reposition the PROG RFID jumper in the rest position 7: the procedure is
NOT terminated automatically!
Once programming has been completed, by pressing the
plus the desired code and
opening control and relay 1 or 2.
Exiting Programming. Briefl y press the PROG key on the power
supply: the PROG LEDs and the LEDs on the entry panels will
go out. NOTE. If no action is performed, the procedure will end
automatically after 30 minutes.
beep
beep
4
Badge. Bring a badge/tag up to the reader of any entry panel that
has already been addressed 3 and, after the confi rmation beep,
press the key (group) to which the code should be assigned 4. If
the maximum permitted number is exceeded (5) for each group,
an error tone will be generated.
and key in the
once again and key in the
8 , it is possible to activate the door
key on the
6 (or press the group key). If
key

Publicité