Framing
•
Approved for combustible floor under and in front of
the appliance.
•
Combustible wall finish may contact the sides of the
heater's black frame.
•
Non-combustible wall finish may be required above the
heater, between the header and the backing plate—
see Wall Finish Detail & Mantel Clearances diagram.
Brackets on the rear of the backing plate to limit the
bottom height of:
•
the combustible wall finish
above the 534 heater,
or
•
the non-combustible
wall finish above the
535 heater.
Installation
1.
Install the heater into framed cavity as described in these instructions and com-
plete the remainder of the installation as per instructions packed with heater.
Finish the wall up to the perimeter of the black frame at sides of the heater and to
the brackets on the rear of the backing plate, at the top. Ensure that the wall finish
is flush or slightly in front of the black frame. Allow for height of finished hearth or
floor, or steel backing plate will not install.
2.
Remove the existing top heat baffle supplied with the heater and replace it with
the heat baffle supplied with this kit using the same 3 screws. Ensure the baffle
offsets upwards.
All manuals and user guides at all-guides.com
Framing Cavity
"A"
Combustible
mantel or
shelf
Wall Finish
Non-combustible
material above
535 model only
613 Backing Plate
"B"
31-3/4"
29-3/4"
Wall Finish Detail & Mantel Clearances
Mantel
"
4"
depth A
Mantel
3" 35" 38" 40" 4" 44"
height B
LH Frame
Header
36" from floor
to bottom
of header
Angle Support
Lower limit of
combustible
wall finish on 534
31-1/4"
from floor
534/535
Black Frame
6"
8"
10" 1"