Error/Fault
Pump will not switch off.
If you can't fix the fault yourself, contact your nearest
vendor. Please be aware that any improper repairs
will also invalidate the warranty and additional costs
may be incurred.
Disposal
Disposal of the appliance
A crossed-out wheelie bin icon means: Bat-
teries and rechargeable batteries, electrical
or electronic devices must not be disposed of
with household waste. They may contain
substances that are harmful to the environ-
ment and human health.
Consumers must dispose of waste electrical devices,
spent portable batteries and rechargeable batteries
separately from household waste at an official collec-
tion point to ensure that these items are processed
correctly. The product can be returned free of charge
in accordance with the legal requirements, for exam-
ple through a municipal waste disposal company or a
dealer.
Batteries, rechargeable batteries and lamps
that are not permanently installed in waste
electrical equipment and can be removed in
a non-destructive way must be removed and
disposed of separately before disposal of the equip-
ment. Lithium batteries and rechargeable battery
packs of all systems are only to be handed in to the
waste collection points in a discharged state. The bat-
teries must always be protected against short circuits
by taping off the poles.
All end users are responsible for deleting any per-
sonal data stored on waste devices prior to their dis-
posal.
Disposal of the packaging
The packaging consists of cardboard and
correspondingly marked plastics that can
be recycled.
– Make these materials available for recy-
cling.
Technical data
Item number
Model
Rated voltage
Capacity
Protection class
Characteristic curve
Cause
Pump block or defective?
Air in the pump or in the intake line? Fill pump housing with water.
Modified suction environment in
fountain (fountain e. g. too sandy)?
Switch off level has been set too
high?
Pressure side leaky?
118664
HWA 3500
230 V~, 50 Hz
800 W
IPX4
► P. 4, fig. 3
Remedy
Clean the pump with clean water
and remove the cause of the con-
tamination.
In the event of an intake line with
non-return valve, fill the intake line
with water as well.
Check fountain and water quality.
Contact your local vendor.
Item number
max. start frequency per
hour
Switch on pressure (set
ex-works)
Switch off pressure (set
ex-works)
Max. supply height
Max. suction level
min. through-flow volume 20 l/min
Max. conveyance volume 3200 l/h
max. liquid temperature
Diameter of pressure line 25 mm (1")
Diameter of intake line
Accessories
Accessories are available from your local vendor.
GB
118664
30×
0,15 MPa (1,5 bar)
0,3 MPa (3 bar)
38 m
8 m
35 °C
25 mm (1")
27