5.4.
Filter and piston ring maintenance
After 500 hours of operation, clean or replace the air filter and clean the delivery valve. After 5000
hours of operation, replace the piston ring.
5.5.
Annual pressure testing
Perform a pressure test on the tank once a year. Inspect both the inside and outside of the tank to
ensure there are no serious cracks or rust. If the tank fails any of these checks, it must be scrapped.
6. Troubles and remedies
Warning: Before performing any maintenance or troubleshooting, disconnect the power supply and
release all air pressure from the tank to avoid potential danger.
Trouble
Motor unable running
and have no voice
Motor has power but
does not rotate or
rotates slowly
Overload protector cuts
off power repeatedly
Air compressor loses
pressure or turns off
Air contains too much
water
Air compressor runs
without stopping
Air compressor shakes
Pressure cannot
increase or cannot
reach the rated level
Possible cause
1.
Not connected to power.
2.
Pressure switch is off.
3.
Fuse is blown.
4.
Overload protector is engaged.
5.
Pressure switch is faulty.
6.
Stator winding is damaged.
1.
Voltage is too low
2.
Motor winding has a short circuit or
is open.
3.
Non-return valve or pressure switch
is faulty.
1.
Voltage is too low.
2.
Poor ventilation or excessively high
temperature.
1.
Gas circuit connections are loose, or
there is air leakage.
2.
Drain valve is open.
3.
Check valve is open.
1.
The tank contains too much water.
2.
Humid environment.
1.
Pressure switch is broken.
2.
Air leakage.
1.
Fastener is loose.
2.
Foot pad is broken or loose.
1.
Drain water valve is open.
2.
Filter is blocked.
3.
Gas circuit connector is loose.
4.
Valve plate or gasket is broken.
5.
Excessive wear on the piston or
cylinder.
EN
1. Check the plug and switch.
2. Turn on the switch and identify the
cause.
3. Replace the fuse.
4. Restart the motor after it cools (wait
15 minutes).
5. Contact the service center.
6. Replace the stator.
1. Check the voltage (ensure it's not
lower than 200V).
2. Contact the service center.
3. Contact the service center.
1. Check the fuse. Ensure the machine
is not powered from other devices.
2. Contact the service center.
1. Check the voltage (ensure it's not
below 10% of the rated value).
2. Close the drain valve.
3. Contact the service center.
1. Drain the water from the tank.
2. Use in a drier environment or install
an oil-water separator.
1. Replace the switch.
2. Check for leaks and repair.
1. Check and repair fasteners.
2. Replace the foot pad.
1. Tighten the drain water valve.
2. Clean or replace the filter.
3. Tighten the gas circuit bolt.
4. Replace the gasket or valve plate.
5. Replace the piston or cylinder.
Remedies