Télécharger Imprimer la page
Empire Comfort Systems DVCT30CBN9-1 Manuel D'installation
Empire Comfort Systems DVCT30CBN9-1 Manuel D'installation

Empire Comfort Systems DVCT30CBN9-1 Manuel D'installation

Publicité

Liens rapides

Model
DVCT30CBN9-1
This conversion kit must be installed by an Empire Comfort Systems, distributor (or other qualified
agency¹)* in accordance with the manufacturer's instructions and all codes and requirements of the
authority having jurisdiction. Failure to follow instructions could result in serious injury or property
damage. The qualified agency performing this conversion assumes responsibility.
National Fuel Gas Code Z223.1 (Latest Edition)
1
*The term "qualified agency" means any individual, firm, corporation or company which either in person
or through a representative is engaged in and is responsible for (a) the installation of gas piping or (b) the
connection, installation repair, or servicing of equipment, who is experienced in such work, familiar with
all precautions required, and has complied with all the requirements of the authority having jurisdiction.
Perform the safety shutdown test any time work is done on a gas system to avoid the possibility of fire
or explosion with property damage, personal injury or loss of life.
CHECK SAFETY SHUTDOWN SYSTEM
Intermittent Pilot System
1. Turn "OFF" using remote control. Main burner and pilot should go off.
2. Pilot gas flow should stop within 30 seconds.
Part Description
Main Burner Orifice, Front
Main Burner Orifice, Rear
SIT Gas Valve Conversion Kit
Gas Conversion Label
Target
TOOLS NEEDED:
Standard screwdriver
1/4 inch hex driver
GAS INPUT FOR DIRECT VENT FIREPLACE CONVERTED TO NATURAL GAS:
DVCT30CBN95P (Propane) - 30,000 BTU per hour
The direct-vent gas fireplace when converted to Natural Gas will have a manifold pressure of approximately 3.5 inches
w.c. (.871 kPa) at the valve outlet with the inlet pressure to the valve from a minimum of 4.5 inches w.c. (1.120 kPa) for
the purpose of input adjustment to a maximum of 14.0 inches w.c. (3.484 kPa).
41346-1-0220
GAS CONVERSION INSTRUCTIONS
DIRECT - VENT GAS FIREPLACE
CONVERSION KITS
Part No.
38290
FOR CONVERSION TO NATURAL GAS
CHECK THE SAFETY SHUTDOWN PERFORMANCE
38290
P185 (#52)
P311 (#47)
R11381
1224
38042
5/16 inch hex driver
7/16-inch wrench
Empire Comfort Systems Inc. • Belleville, IL
DVCT35CBN9-1
WARNING
WARNING
PARTS LIST
Conversion Kits
38500
P245 (#50)
P319 (2.40 mm)
R11381
1224
38042
7/16 inch deep socket
DVCT35CBN95P (Natural) - 39,000 BTU per hour
Model
Quantity Supplied
Part No.
38500
1
1
1
1
2
Page 1

Publicité

loading

Sommaire des Matières pour Empire Comfort Systems DVCT30CBN9-1

  • Page 1 FOR CONVERSION TO NATURAL GAS WARNING This conversion kit must be installed by an Empire Comfort Systems, distributor (or other qualified agency¹)* in accordance with the manufacturer’s instructions and all codes and requirements of the authority having jurisdiction. Failure to follow instructions could result in serious injury or property damage.
  • Page 2 Use a 7/16 inch deep socket wrench to remove orifices. See Figure 6. Figure 2 ORIFICE Remove (2) screws holding pilot assembly to burner pan. This will allow pilot assembly to drop. See Figure 3. Figure 6 Figure 3 Page 2 Empire Comfort Systems Inc. • Belleville, IL 41346-1-0220...
  • Page 3 If fireplace is not installed or project registration card has not been returned to Empire Comfort Systems, check off type of gas converted to on the card. Also indicate conversion by adding “Conv.” behind type of gas.
  • Page 4 Empire Comfort Systems Inc. Belleville, IL If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. www.empirecomfort.com Page 4 41346-1-0220...
  • Page 5 38500 POUR CONVERSION AU GAZ NATUREL AVERTISSEMENT Ce nécessaire de conversion doit être installé par un distributeur Empire Comfort Systems Inc. (ou une agence qualifiée )* conformément aux instructions du fabricant et à tous les codes et exigences de l’autorité ayant juridiction. Le défaut de respecter les directives pourrait résulter en de grave blessure ou dégâts matériels.
  • Page 6 Figure 2 ORIFICE Retirer deux (2) vis qui fixent la veilleuse à la cuvette du brûleur. Ceci permet à l’ensemble de veilleuse de tomber. Voir Figure 3. Figure 6 Figure 3 Page 2 Empire Comfort Systems Inc. • Belleville, IL 41346-1-0220...
  • Page 7 Si le foyer n’est pas installé ou que la carte d’enregistrement du projet n’a pas été retournée à Empire Comfort Systems, cocher le type de gaz converti sur la carte. Indiquer également la conversion en ajoutant « Conv. » derrière le type de gaz.
  • Page 8 Empire Comfort Systems Inc. Belleville, IL Pour toute question générale concernant nos produits, veuillez nous envoyer un courriel à info@empirecomfort.com. Pour toute question d’entretien ou de réparation, veuillez communiquer avec votre revendeur. www.empirecomfort.com Page 4 41346-1-0220...

Ce manuel est également adapté pour:

Dvct35cbn9-13829038500