Télécharger Imprimer la page

EBERTH FC1-GM25S Mode D'emploi page 40

Publicité

Table 3
Error
Engine does not start
Device starts up, but
blocks at low load
and may switch off
automatically
Motor does not
produce any power
EN
V. 1.2
Troubleshooting
Possible cause
Mains voltage missing
Connection cable
defective
Motor or switch
connections not in order
Motor or switch defective
Extension cable too long
or cross-section too small
Socket too far from the
main connection and too
small cross-section of the
connection cable
Insufficient cross-section of
the extension cable
Overload
Solution
Check the cables.
Have them checked
or replaced. (qualified
electrician)
Have it checked by
Elektrokraft.
Extension cable at least 1.5
mm² with a maximum length
of 25 m.
Shorter cable cross-section at
least 2.5 mm².
Extension cable at least 1.5
mm² with a maximum length
of 25 m.
Check the device.
17