Cleaning the device
Always disconnect the power supply from the socket before cleaning!
Clean the appliance with a dry cloth. Do not use chemicals. You can also clean the air
inlets with a vacuum cleaner (it is best to clean the unit outdoors).
The particle sensor of the device is maintenance-free and does not normally have to be
cleaned. The cover behind which the particle sensor is located provides easy access in
the event of a defect.
Malfunctions and solutions
Current operating instructions can be found at www.comedes.com
Turn off the unit immediately and contact your dealer if any of the following problems
occur:
Fuse's blown.
Foreign material gets into the device.
The AC adapter or power cord heats up.
It is smoke, or burn smell perceptible.
Do not open the unit without authorized service personnel. However, you can
Check the following causes of malfunction yourself:
The device cannot be switched on:
Is the power supply plugged in correctly?
Has the fuse blown or is there no voltage at the socket?
Is the mains switch on the device switched on?
The air flow at the outlet opening is lower:
Is the filter too dirty or clogged?
Is the sleep function activated?
The device is disproportionately loud:
Does the device stand on an uneven surface?
Is the filter too dirty or clogged?
The device emits an unpleasant/unusual odor:
Is the unit used in rooms with high humidity or has the filter become wet?