B. LED Function
1. LU 361 PE and LU 361 PE-S has one RED LED (See Fig. 17) . It lights for
2 secs. Once the sensor is triggered and uncontrolled by LUX.
2. LED can be regarded as indicator when performing a walk test without
connecting any loads.
Fig. 17
C. Walk Test
The purpose of the walk test is to check and adjust the motion sensor
detection range. Turn "METER" knob to "7m", "TIME 1" knob to "test", then
you can carry out a walk test and it is uncontrolled by LUX (See Fig. 18) .
24
Note:
• When first time switches the power n or power is re-supplied again after
the power is shut off, LED will turn on for 40 secs. then turn off. During
the time of warming up, there is no output for LOAD I if it is in test &
impulse mode, otherwise it has permanent output as LOAD II. Once any
activities are detected after warming up period (40 secs.), LOAD I and
LOAD II will operate according to prior settings. If there is no triggering
in 20 secs. after warming up period, LOAD I and LOAD II will turn off
automatically and won't be controlled by the settings of Time 1 & Time 2.
Fig. 18