THERMASGARD
Measuring ranges [ °C ]
(adjustable)
– 20...+ 150 °C
– 50... + 50 °C
– 20... + 80 °C
– 30... + 60 °C
0... + 40 °C
0... + 50 °C (default)
0...+ 100 °C
0...+ 150 °C
TEMPERATURE RANGES:
When selecting measuring transducer ranges, it is necessary to ensure that
the maximum temperatures permissible for sensor ⁄ housing are not exceeded !
Ambient temperature for measuring transducers:
– 30 ...+ 70 °C / –22...+158 °F
Apparent ohmic resistance = see load resistance diagram
THERMASGARD
®
Sleeve sensor with temperature measuring transducer
HFTM
Type ⁄ WG01I
Output
HFTM
with cable gland
(2-wire)
HFTM - I
H F T M - I
4...20 mA
H F T M - I L C D
4...20 mA
(3-wire AOS)
HFTM - A
H F T M - A
0 -10 V / 4...20 mA
H F T M - A L C D
0 -10 V / 4...20 mA
Housing variant:
Cable connection with cable gland
HFTM - Q
with M12 connector
HFTM - I Q
(2-wire)
H F T M - I Q
4...20 mA
H F T M - I Q L C D
4...20 mA
HFTM - A Q
(3-wire AOS)
H F T M - A Q
0 -10 V / 4...20 mA
H F T M - A Q L C D
0 -10 V / 4...20 mA
Housing variant "Q":
Cable connection with M12 connector (male, 5-pin, A-code)
Automatic Output
Patented analogueinterface (patent no. DE 10 2015 015 941 B4)
Switching (AOS):
Unit automatically detects the required output type 0 -10 V or 4...20 mA.
Extra charge:
other measuring ranges optional
Protection type IP 68 (Sensor sleeve watertight compound-filled)
2-wire connecting leads, per running meter (silicone / PTFE / glass fibre)
Other lengths of protection sleeve optional
ACCESSORIES
THE - xx
Immersion sleeve, stainless steel V4A (1.4571) or nickel-plated brass, Ø = 9 mm / 0.35 in
Special accessories for M12 connector see catalog or online shop under accessories !
®
HFTM
Measuring ranges [ °F ]
DIP
DIP
DIP
1
2
3
(adjustable)
O N
O N
O N
OFF
– 58...+ 122 °F
O N
O N
O N
OFF
O N
OFF
OFF
– 22...+ 140 °F
O N
O N
O N
OFF
OFF
OFF
O N
O N
OFF
OFF
OFF
OFF
OFF
– 4...+ 302 °F
– 4...+ 176 °F
32...+ 104 °F
32...+ 122 °F (default)
32...+ 212 °F
32...+ 302 °F
Type
Remote sensor
Remote sensor
Remote sensor
Remote sensor
Remote sensor
Remote Sensor
Remote sensor
Remote Sensor
11
Readout in the display
(switchable)
Imperial
SI (default)
Readout in the display
Temperature [°C] → [°F]
The display value depends
on the set unit system (DIP 4).
Display
Item No.
= Q
110 1 -1152-021 9-920
110 1-1152 -221 9-9 20
110 1 -115E -02 19-920
110 1-115E -22 19-920
???
200 1-2111-210 0-001
200 1-2112-210 0-001
2001-2111-B100-001
2001-2112-B100-001
on request
on request
Rev. Data-V20
DIP
4
[°F]
O N
[°C]
OFF