ASSEMBLY
General
GB 12
Clearance required
The distance between the underside of the extractor hood and the hob
should be at least 550 mm. For gas hobs, this distance should be a
minimum of 650 mm.
Mounting of the hood between two hanging cupboards
• Drill 2 holes of 2,5 mm diameter on the side of the hanging
cupboards as shown in fig. 1 considering also the thickness of the
front panel, so that the hood remains at the same level of the side
hanging cupboards.
• Fix the hood to the hanging cupboards through 4 screws, which are
appropriate to that kind of cupboard.
• Close the space, which eventually remains between the hood
and the wall adjusting the spacer (L) by acting on the appropriate
screws (P) (fig. 1).
Mounting of the hood on the wall
• Drill 6 holes on the wall as shown in (fig. 2). Fix the spacer (L) on
the wall at the right height, according to the depth of the hanging
cupboards (fig. 2).
• Adjust the position of the upper clamps (M) (fig. 2), according to the
depth of the side hanging cupboards.
• Fix the hood on the wall through 4 screws and dowels with
expanding plug , which are appropriate to that kind of wall (ex.
concrete, plasterboard, etc.).
• Fix the hood to the spacer through the screws (P) (fig. 1).
Fixing of the front panel
• Take off the door (E) by removing the grill (G) and pulling at the
same time the special spring locking knobs (H) (fig. 3).
• Fix the door on the front panel through the screws at the level
indicated in (fig. 3).
• Replace the door by inserting it in the upper and lower slides until
the spring locking knobs (H) are released.