BATTERy CHARGER
CHARgINg PROCEDURE (See Figure 5. )
The battery is not shipped fully charged. It is recommended to fully charge before first
N O T E :
use to ensure that maximum run time can be achieved. This lithium-ion battery will not develop a
memory and may be charged at any time.
1. Plug the charger into an AC power outlet.
2. Insert the battery pack (3) into the charger.
This is a diagnostic charger. The Charger LED Lights will illuminate in specific order to
communicate the current battery status. They are as follows:
CHARGING PROCEDURE (LED INDICATOR)
BATTERy IS CHARGING:
fULLy CHARGED:
BATTERy IS TOO WARM:
(REMOVE fOR APPROX. 30
MINUTES TO ALLOW TO COOL)
NO BATTERy PRESENT
DEfECTIVE BATTERy:
(REMOVE AND REPLACE WITH
NEW BATTERy If THIS OCCURS)
Fig. 5
CHECKINg THE CHARgE
If the battery pack does not charge properly:
• Check the current at the power outlet with another tool. Make sure that the outlet is not turned
off.
• Check that the charger contacts have not been shorted by debris or foreign material.
• If the surrounding air temperature is not normal room temperature, move the charger and
battery pack to a location where the temperature is between 45˚F and 104˚F .
RED
RED
RED
GREEN
RED
ORANGE
RED
GREEN
RED
RED
BLINKING
BLINKING
15
3
1
2