Maintenance and cleaning:

Before completing any maintenance operation, adopt the following precautions:
- Make sure that the main line switch is disengaged.
- Make sure that all stove parts are cold.
- Make sure that the ashes are completely cold.
- Always operate with equipment that is appropriate for maintenance.
Once maintenance has been completed, re-install all safety guards before placing it back in service. The stove requires very little
maintenance id quality pellet is used. It is not therefore easy to establish what cleaning frequency is required. Pellet quality and
combustion adjustment are decisive. This is why it is important for an authorised technician to ignite the stove the first time.

Cleaning the tank and screw at the end of the season:

Prior to intervention by the authorised Technical Service Centre for mandatory seasonal cleaning, as required by the regulations, it
is advisable to let the pellets burn out in the tank so that the pellet remains and sawdust can be vacuumed from the bottom and from
the screw. Run one or two empty loading cycles on the screw to remove the pellets, DISCONNECT the power supply by turning the
I/O switch on the back and pull the plug out from the electrical socket. The protective grille inside the tank can now be removed, if
required. Start collecting the pellets and the sawdust remains from the bottom of the tank and from the pellet drop hole, and also from
the firebox, with an ash vacuum cleaner. This prevents the pellets left in the tank and in the load screw from dampening and creating
plugs which are then difficult to remove even for the Technical Service Centre, forcing it to disassemble the part with subsequent
additional costs. Put the protective grille back in place after cleaning and before reconnecting the power supply.

Combustion chamber cleaning:

The stove requires a simple yet frequent cleaning in order to guarantee suitable yield and regular operation. Vacuum the combustion
chamber every day using a bin ash vacuum, making sure that the ashes are completely cold.