Technical Specifications
Height
Width
Depth
Weight
Smoke exit pipe diameter
Air inlet
Ducting
Maximum heat volume
Thermal power | reduced - nominal
Absorbed electrical power
Power supply
Tank capacity
Min-max autonomy
Performance
CO at 13%O 2
Smoke mass
Minimum draft
Smoke temperature
Consumption
The data shown below is indicative and not a commitment and may change based on the pellet type used. Elledi reserves the right to make any changes in
order to improve product performance.
Minimum distance from flammable materials
MODEL
Star 10.2 C
R = right side
150 mm
L = left side
150 mm
B = back
100 mm
A = fron
800 mm
Preliminary operations
Electrical connection
Connect the power supply cable, first on the back of the stove and then to an outlet on an accessible wall.
Connect the stove to an earthed electrical system
Only plug the stove's power cable in after it has been installed and assembled, and make sure it is accessible
after installation.Be careful not to let the power cable (or any other cables outside the equipment) touch any hot
parts. The switch in figure I/O must be positioned on I to power the stove. If there is no electrical power, check
the state of the fuse located in the box under the switch (4A fuse). During a period of non use, it is recommended
to remove the stove power supply cable.
What needs to be checked before turning on the stove
Check that all components that may burn have been extracted and removed from the combustion chamber or glass (instructions or
various adhesive labels).
Before turning on the equipment, check correct positioning of the brazier on its support base and that the door and the ashes drawer
are closed properly.
Loading pellet
The fuel is loaded by opening the door and inserting pellet from the upper part of the stove. During the loading phase, avoid that the
pellet bag comes in contact with hot surfaces. Do not let the pellet bag fall hard on the stove.
DO NOT INTRODUCE INTO THE TANK ANY OTHER TYPE OF FUEL OTHER THAN PELLET CONFORMING TO
DO NOT INTRODUCE INTO THE TANK ANY OTHER TYPE OF FUEL OTHER THAN PELLET CONFORMING TO
THE PREVIOUSLY EXPLAINED SPECIFICATIONS.
THE PREVIOUSLY EXPLAINED SPECIFICATIONS.
STAR 10.2 C- STAR 12.2 C
Use and maintenance manual
measurement
| reduced - nominal
| reduced - nominal
| reduced - nominal
| reduced - nominal
| reduced - nominal
MODEL
R = right side
L = left side
B = back
A= fron
Unit of
Star 10.2 C
mm
1106
mm
454
mm
614
kg
105
mm
80
mm
50
mm
80
m 3
240
kW
4,8 - 10,0
W
275
V - Hz
230 - 50
kg
20
h
20 - 9
%
91,3 - 87,1
%
0,019 - 0,010
g/s
4,6 - 8,9
Pa
10
°C
117 - 181
Kg/h
1,0 - 2,3
Star 10.2 C
200 mm
200 mm
100 mm
800 mm
Rev.1 03/08/2017
Page 45
Star 12.2 C
1186
455
614
115
80
50
80
285
4,8
275
230 - 50
24
24 - 9
91,3 - 87,4
0,019 - 0,004
4,6 - 9,3
10
117 - 195
1,0 - 2,7
L
A
EN
B
R