Alarms (reference table)

CODE
TITLE
AL 01
BLACK OUT
AL 02
SMOKE SENSOR
AL 03
SMOKE OVERTEMP.
EXTRACTOR MALFUNCTION-
AL 04
ING
AL 05
START-UP FAILURE
AL 06
PELLET FINISHED
SAFETY THERMAL SWITCH
AL 07
WITH MANUAL RE-ARM
AL 08
DEPRESSION
AL 11
FLAME FAILURE
EXTRACTOR ROTATION
AL 12
FAILURE
AL 14
FEED SCREW PHASE
AL 15
FEED SCREW TRIAC
! IMPORTANT
STAR 10.2 C- STAR 12.2 C
Use and maintenance manual
- Missing voltage during the work phase
- The smoke sensor is malfunctioning
- The smoke sensor is disconnected from the
electronic board
- Combustion in the brazier is not optimal
due to clogging in the brazier or within
internal stove passages
- The centrifugal fan (if present) is
defective or damaged
- Encoder smoke extractor not working or not
connected correctly
- No power to the smoke extractor
- The smoke extractor is blocked
- The pellet tank is empty
- Pellet calibration and suction during the
ignition phase is unsuitable.
- The resistance for ignition is defective or not
in position
- The pellet tank is empty.
- The motor reducer is not loading the pellet
- Lack of pellet load
- The manual re-arm thermostat
connected to the hopper has tripped
- Combustion in the brazier is not optimal
due to clogging in the brazier or within
internal stove passages.
- The chimney is blocked.
- The vacuum state is malfunctioning.
- The pellet tank is empty
- Pellet calibration and suction during switch-on
is inappropriate
- The smoke extractor rotations have a 15% ef-
ficiency loss due to fan obstruction.
- Motor electric voltage failure during pellet
loading.
- Electronic board malfunction detected in the
pellet loading motor control
EVERY ALARM CONDITION CAUSES THE STOVE TO SWITCH OFF IMMEDIATELY. PRESSING THE P1-2 KEY ON
THE SCREEN FOR A FEW SECONDS, THE ALARM MAY BE CANCELLED.
REASON
Page 54
RESOLUTION
- Press the shut-off key and repeat
stove start-up
- If the problem remains, contact After-Sales
Service.
- Contact After-Sales Service
- Contact After-Sales Service
- Shut-off the stove, clean the brazier, use the
pipe unit cleaning and finally adjust the
combustion using the Pellet/Air setting
- Contact After-Sales Service
- If the problem remains, contact After-Sales
Service.
- Contact After-Sales Service
- Contact After-Sales Service
- Contact After-Sales Service
- Verify pellet presence in the tank.
Load if needed.
- Contact After-Sales Service
- Contact After-Sales Service
- Verify pellet presence in the tank.
Load if needed
- Empty the tank to verify that
inside there are no fallen objects that
may prevent correct
auger operation.
- Adjust the pellet set from "SET ARIA/PELLET"
(Air/Pellet Set)
- If the problem remains, contact After-Sales
Service
- Re-arm the thermostat by pressing the button
on the
back of the stove.
- Shut-off the stove, clean the brazier, use the
pipe unit cleaning and finally adjust the
combustion using the Pellet/Air setting
- Contact After-Sales Service
- Verify that the chimney is free and
clean.
- Contact After-Sales Service
- Check the tank inside for pellets
- Contact your local Technical Support Centre
- Contact your local Technical Support Centre
- Contact your local Technical Support Centre
- Contact your local Technical Support Centre