IMPORTANT SAFETY INSTRUCTIONS
electrical cord. Locate the cord where it will not be damaged by lawn mowers, hedge trimmers
and other equipment. Connect to a grounded, grounding type receptacle only.
US
plug).The GFCI must be tested before each use. With the product operating, open the service
door. When the product stops operating, this merely indicates that the door is equipped with an
electrical interlock. Next, push the test button on the GFCI and close the service door. The product
should not operate. Now open the service door, push the reset button on the GFCI and close the
service door.The product should now operate normally. When the product fails to operate in this
thorized access by children. To avoid accidents, ensure that children cannot use this spa unless
they are supervised at all times.
ration.Never use a worn or damaged cover: it will not provide the level of protection required to
prevent unsupervised access to the spa by a child. Always lock the spa cover after each use.
7. DANGER – Risk of Electric Shock. Install at least 5 feet (1.5 m) from all metal surfaces. As an
alternative, a spa may be installed within 5 feet of metal surfaces if each metal surface is perma
nently connected by a minimum 8 AWG (8.4 mm²) ,6 AWG (13.3mm²) solid copper conductor to
the wire connector on the terminal box that is provided for this purpose.
telephone, radio or television within 1.5m (5 feet) of a spa tub. Do not use the spa when it is
raining,thundering or lightning.
children and when spa use exceeds 10 minutes. The water in a spa should never exceed 40°C
(104°F). Water temperatures between 38°C(100°F) and 40°C(104°F) are considered safe for a
healthy adult.