TARING
Zero the scale by pressing the ZERO key if necessary.
The "ZERO" indicator will be on.
Place a container on the pallet, display shows weight.
Press the TARE key to tare the scale. The weight that was
displayed is stored as the tare value and that value is
subtracted from the display. "
The "GROSS" indicator will be off and "NET" indicator on.
As product is added, only the weight of the product will
be shown. The scale could be tared a second time if
another type of product was to be added to the first one.
Again, only the weight that is added after taring will be
displayed.
When the container is removed, a negative value will be
shown. If the scale was tared just before removing the
container, this value is the gross weight of the container plus
all product that was removed. The "ZERO" indicator will be
on because the pallet is back to the same condition it was
when the ZERO key was last pressed. Press TARE key again
to escape "NET" mode.
WEIGHING
Put the control lever in the LOWER position and lower the
truck to lowest position.
Press the ON/OFF key to turn the scale on. After the
indicator counts down, the display will zero. Place the
forks under the pallet. While balancing load as evenly
as possible, put lever in ASCENT position and pump
handle to raise load. Once "STABLE" indicator shows, the
accurate weight of the load is displayed. (Total weight
of pallet and the goods.)
GROSS/NET FUNCTION
This function is only available after TARE function has
been used. Pressing the G/N button will toggle between
total weight (gross) on skid and weight after TARE
function was used (NET).
SELECTING WEIGHING UNITS
Press U key to select desired weighing units (LBS or KG).
PAGE 7 OF 35
OPERATION CONTINUED
0
" (zero) shows on display.
ACCUMULATION
NOTE: Before using Accumulation function,
remove all weight from forks and zero the
scale.
1. Weigh item on scale. Once "STABLE" indicator shows,
press M+ key to store weight in memory.
2. The display will show "
memory for two seconds before returning to normal.
3. The "M+" indicator is on. Remove the weight, allow
the scale to return to zero and put a second weight
on the scale.
4. Press M+ key, the display shows "
new total.
5. Continue until all weights have been added. The
scale can accumulate up to 99 items.
NOTE: Changing weighing units during
Accumulation function will clear memory.
MEMORY RECALL
To view totals in memory, press the M+ key while
0
display reads "
" (zero), and display will show "
('n' is current accumulation times) and then the total
in memory for two seconds. The scale then returns to
normal.
TO CLEAR MEMORY
To clear the accumulated data in memory, press the
M+ key and the G/N key when total weight value is
displayed.
PRETARE
1. To set, press and hold PT key for three seconds to
display current tare value.
2. To manually key in a tare value, use TARE key to
select value and M+ and PT keys to toggle between
active digits.
3. Enter Pretare value and press ZERO key.
4. Display now shows "
select desired pretare item. (0-9 preset items are
available.)
5. Once pretare item is selected, press ZERO key to
store pretare value in memory.
NOTE: Pretare value is displayed while "NET"
indicator is shown on display.
AC 01
" and then the total in
AC 02
" and then the
PtS 0
". Press TARE key to
0924 IH-4564
AC n
"