BATTERY PERFORMANCE
Always use original batteries and AC adapter. Scale is
not intended for use with non-original batteries and/or
battery chargers.
• AC adapter rating is 12V.
• New batteries or batteries stored for long periods of
time may require longer charging times.
• Keep battery at or near room temperature when
charging.
DAILY CHECK AND MAINTENANCE
A daily check of the pallet truck can help prevent
accidents. Give special attention to the wheels, the
axles, the handle, the forks and control lever. The forks
should be unloaded and lowered in the lowest position
when the job is completed.
LUBRICATION
Use motor oil or grease to lubricate all moveable parts.
GENERAL MAINTENANCE
1. Check the oil level every six months. The volume of
oil is about 10.1 fl. oz.
ENTER TECHNICAL PARAMETER MODE
NOTE: Must use 10% of capacity to calibrate.
1. Press ZERO and TARE keys at the same time. The
F1 Unit
display shows "
2. Press TARE key until display shows "
Pn
ZERO key to show "
3. Press in order M+, U and TARE keys to enter technical
parameter setting mode.
4. Press TARE key to select parameter, press ZERO key
to enter value and U key to exit.
5. It may be necessary to use TARE key to set a value
or use M+ and PT keys to move the active digit.
PAGE 10 OF 35
BATTERY OPERATION CONTINUED
OPERATION CONTINUED
".
ProG
" and press
" on the display.
• Do not expose batteries to temperatures below
14ºF (-10ºC) or above 113ºF (45ºC).
• Fully charge battery before first use.
• Batteries should be charged once every three
months at minimum.
• As the battery is used it may fail to hold a full
charge. If the battery life becomes unacceptable,
contact Uline Customer Service at 1-800-295-5510.
MAINTENANCE
2. Use the hydraulic type oil according to temperature
scale below.
TEMPERATURE
23°F–113°F
33.8°F–23°F
EXPEL AIR FROM THE PUMP UNIT
Air may get into the hydraulics due to transportation or
pump disturbances. It can prevent forks from elevating
while pumping in ASCENT position. To expel air: Put
the control lever to the LOWER position, then move the
handle up and down several times.
CALIBRATION
CALIBRATION
1. Enter Technical Parameter Setting mode (see steps
1-3 above) until display shows "
2. Press the TARE key until display shows "
ZERO key to enter and press TARE key until display
shows "
3. Press ZERO key twice and display shows "
Remove all weight from the forks. After "STABLE"
indicator is visible, press the ZERO key.
4. The display shows the calibration weight value. Use
the M+, PT and TARE keys to set the weight value.
NOTE: Use M+ and PT keys to move active digit,
use TARE key to change value. You can also
press G/N to make value zero.
OIL
L-HM68 Hydraulic oil (equivalent to ISO VG68)
L-HM46 Hydraulic oil (equivalent to ISO VG46)
CAL
".
P1 rEF
".
P2 CAL
". Press
UnLd
".
0924 IH-4564