RAISING/LOWERING FORKS
Control lever is located on pallet truck handle and can
be set to three positions: lower, neutral and ascent.
(See Figures 11-13)
1. Tighten set screw on crank link until lower position
on control lever functions properly. (See step 2 of
Handle Installation on page 5).
2. If forks elevate while pumping with control lever
in neutral position, turn set screw clockwise until
pumping the handle no longer elevates forks and
neutral position functions properly.
3. If forks descend while pumping with control lever in
neutral position, turn set screw counter-clockwise
until forks no longer descend.
4. If forks do not descend when control lever is in lower
position, turn set screw clockwise until forks lower
while in lower position.
5. If forks do not elevate while pumping with
control lever in ascent position, turn set screw
counterclockwise until the forks elevate while
pumping in the ascent position. Re-check neutral
and lower positions to ensure proper functioning.
CONTROL LEVER
The control lever can be set in three positions:
Figure 11
Figure 12
Figure 13
PAGE 6 OF 35
OPERATION
Lower:
Push lever up to lower.
the forks
Netral:
To move the load.
Ascent:
Push lever down and
pump handle to raise
the forks.
CHARGING THE BATTERY
Connect AC adapter into the plug on the side of the
control panel. Plug cord into 110/120V AC outlet.
(See Figure 14)
NOTE: Charging time is approximately 15 hours.
Figure 14
BATTERY STATUS (LED INDICATOR)
• Green – Battery is fully charged.
• Red – Battery is charging.
ZEROING THE DISPLAY
Press the ZERO key at any time to zero the scale. This
will usually only be necessary when the pallet is empty.
When the zero point is obtained, the display will show
0
"
" (zero).
The scale has an automatic rezeroing function to
account for minor drifting or accumulation of material
on the pallet. However, you may need to press the ZERO
key to rezero the scale if small amounts of weight are
shown when the pallet is empty.
0924 IH-4564