Airflow balancing
Airflow balancing
Balancing must be completed using the VNTBAL2000 Touchscreen
Balancing Control (sold separately). After the unit is balanced, the
wall control may either be left in the home as the ventilator control, or
replaced with a different control for contractors who only use the wall
control for balancing new units.
Note: The HVAC fan needs to be on during balancing if the ventilator is
connected to HVAC ducting.
Entering balancing mode
Use the toggle switch to place the unit in "normal" speed to perform the
balancing. Press the "OPTIONS" menu on the balancing control. During
the initial five second countdown, long press on "AUTO" to enter basic
balancing mode. The supply and exhaust fans should be adjusted on
high speed only and the offsets are proportionally applied to the medium
and low speed automatically. Note that the flashing arrow on the home
indicates whether the exhaust or supply fan is being adjusted.
AUTO
OPTIONS
AUTO
OPTIONS
NEXT
Balancing chart 1.5
Fresh air / Air frais Stale air / Air vicié
IN. W.G.
Pascal
CFM
(Pa)
PCM
0.60
149
186
0.58
144
182
0.56
139
177
0.54
135
172
0.52
130
167
0.50
125
162
0.48
120
157
0.46
115
152
0.44
110
146
0.42
105
141
0.40
100
136
Stage 1
(adjust level of exhaust fan in high speed):
In this step, balance exhaust fan and measure airflow on
the exhaust air side.
Pressing on "up" or "down" will adjust the fan speed in
increments of 1%. The fan can be adjusted to -60% of
MANUAL
maximum fan speed.
Using the balancing chart on the front of the ventilator,
adjust the exhaust airflow to the desired value. Once the
desired exhaust airflow is reached, press "NEXT" and move
on to the next stage.
Stage 2
(balance supply fan only in high speed):
In this step, balance supply fan and measure airflow on the
supply air side.
Pressing on "up" or "down" will adjust the fan speed in
increments of 1%. The fan can be adjusted to -60% of
maximum fan speed.
Using the balancing chart on the front of the ventilator,
adjust the supply airflow to match the exhaust airflow.
MANUAL
Press "NEXT" to complete balancing.
*The supply and exhaust offset values will be proportionally
applied to low and medium speed as well.
CFM
L/s
L/s
PCM
88
187
88
86
184
87
84
180
85
81
176
83
79
173
82
76
169
80
74
165
78
72
161
76
69
156
74
67
152
72
64
147
69
HIGH
HIGH
HIGH
LOW
LOW
LOW
Fresh Air
from Outside
Stale Air
to Outside
LOW
LOW
LOW
HAUT
HAUT
HAUT
BAS
BAS
BAS
Aspiration
d'air frais
Évacuation
d'air vicié
BAS
BAS
BAS
Balancing chart 2.0
Pressure / Pression
Fresh air / Air frais Stale air / Air vicié
IN. W.G.
Pascal
PO. d'eau
(Pa)
0.36
90
0.34
85
0.32
80
0.30
75
0.28
70
0.26
65
0.24
60
Fresh
Air
Stale Air
from Home
Fresh Air
to Home
HIGH
HIGH
HIGH
Stale
Air
AUTO
MANUAL
Air frais
OPTIONS
0 %
ADJUST
Aspiration
d'air vicié
NEXT
Distribution
d'air frais
HAUT
HAUT
HAUT
AUTO
MANUAL
Air vicié
OPTIONS
0 %
BALANCE
NEXT
CFM
CFM
L/s
PCM
PCM
216
102
-
209
99
222
200
94
214
192
91
207
183
86
198
173
82
189
163
77
180
L/s
-
105
101
98
93
89
85