VNTBAL2000 Touchscreen Balancing Control
Compatible with ventilator models:
•
VNT5150E2000
•
VNT5150H2000
•
VNT5200E2000
•
VNT5200H2000
Warning
Always disconnect the unit before performing maintenance or making any connections. Failure to discon-
nect power could result in electrical shock or damage, to the wall control or the electronic components.
Caution
Follow the instruction to insure proper operation and functionality of the control and ventilation system.
– Only one wall control per ventilation system is possible
– Keep wall control and low voltage wires minimum 2 feet (610 mm) away from motors, light ballast,
dimmers and electrical panels
– Do not route wall control low voltage wires alongside high voltage wires
– Recommended type of wire: LVT 18/4 CSA/UL
Best Practices
For optimal operation of the ventilation control, the following best practices are recommended during installation:
•
The location of the ventilation control could affect the optimum performance. Therefore, it is recommended that
the wall control be installed in a central location, away from direct sunlight and other sources of direct heat or
cold such as an outside wall or adjacent to windows.
•
Do not install ventilation controller on wall where cavity is opened to other areas. Example: Forced air system
return air plenum or in a wall cavity.
INSTALLATION INSTRUCTIONS
33-00677EF-01