UK: INSTRUCTION MANUAL
RECOMMENDED TEMPERATURES FOR COMMON FOOD:
Drinks
Fruits
Vegetable
5°C/41°F
5~8°C/41~46°F
3~10°C/37~50°F
6. CARE AND MAINTENANCE
Cleaning:
• Switch off and unplug the device first to avoid electric shock.
• Use a wet cloth to clean the device and then wipe with a dry cloth.
• Do not soak the cool box in water or clean it under running water.
• Do not use abrasive cleaning agents during cleaning as these can damage the device.
Storage:
If the device will not be in use for a long time, please follow these instructions:
• Switch off and unplug the device.
• Take out all the items stored in the device.
• Wipe off excess water with a soft rag.
• Put the cool box in a cool and dry place.
• Leave the lid slightly open to prevent odors from forming.
• Recommended storage environment: Ambient temperature: 25°C, ambient humidity: ≤ 75%.
Defrosting:
• Humidity can form frost in the interior of the cooling device or on the evaporator. This reduces the cooling
capacity. Defrost the device in good time to avoid this.
• Switch off and unplug the device first to avoid electric shock.
• Take out all the items stored in the device.
• Keep the lid open.
• Wipe off the defrosted water.
Never use hard or pointed tools to remove ice or to free objects frozen onto the device.
Replacing the cool box fuse (15A)
1. Unplug the cable from the mains or 12V socket and the cool box charging port.
2. Pry open the fuse cover with a small flat head screwdriver in the cool box charging port. Replace fuse with
a new one that has the same rating (ATO regular blade fuse 15A).
3. Re-assemble the charging port in the reverse order.
6
Ready-to-
Wine
Ice cream
Meat
eat food
4°C/39°F
l0°C/50°F
-l0°C/14°F
-l8°C/0°F
7. TROUBLESHOOTING
Issues
• Check if the switch is on.
• Check if the plug and socket are properly connected.
• Check if the fuse has been burnt.
Cool box does
not work
• Check if the power supply is malfunctioned.
• Switching the cool box on/off frequently may cause start
delay of the compressor.
• The lid is opened frequently.
Cool box compartments
• A large amount of warm or hot food was stored recently.
are too warm
• The cool box has been disconnected for a long time
Food is frozen
• The temperature was set too low
There is "water flow"
noise from inside the
• It is a normal phenomenon, caused by the flow of refrigerant.
cool box
There are waterdrops
• It is a normal phenomenon, the moisture will condense to water
around the cool box
when it touches a cold surface of the cool box.
casing or lid gap
• It is a normal phenomenon, the noise will be reduced after the
The compressor is slightly
noisy when starting
compressor works stably.
• Possible cause: low voltage to cool box. Adjust the battery protection
Code Fl displayed
from High to Medium or from Medium to Low.
• Possible cause: condenser fan is overloaded.
Code F2 displayed
Disconnect power to cool box for 5 minutes and re-start.
If the code shows again, contact manufacturer for service.
• Possible cause: the compressor starts too frequently.
Code F3 displayed
Disconnect power to cool box for 5 minutes and re-start.
If the code shows again, contact manufacturer for service.
• Possible cause: compressor not kicking in.
Disconnect power to cool box for 5 minutes and re-start.
Code F4 displayed
If the code shows again, contact manufacturer for service.
• Possible cause: overheating of the compressor and electronics.
Disconnect power to cool box for 5 minutes and re-start.
Code F5 displayed
If the code shows again, contact manufacturer for service.
• Possible cause: no parameter can be detected by the controller.
Code F6 displayed
Disconnect power to cool box for 5 minutes and re-start.
If the code shows again, contact manufacturer for service.
• Possible cause: temperature sensor is faulty.
Code F7 or F8 displayed
Contact manufacturer for service.