4. STORAGE
To put into storage:
The product must be stored away from children.
5. TROUBLESHOOTING
Problem
Charging is not possible.
(Lc)
Battery charge indicator
is continuously illuminated
[ Fig. O2 ]
(Lc)
Battery charge indicator
is not illuminated [ Fig. O2 ]
GAR_14900-56.960.06_2024-10-29.indd 7
GAR_14900-56.960.06_2024-10-29.indd 7
1. Clean the battery charger (see 3. MAINTENANCE).
2. Store the battery charger in a dry, enclosed and frost-
free place.
Possible Cause
The battery is not connected (correctly).
Battery contacts are dirty.
Battery temperature is outside the permis­
sible charging temperature range.
Battery is defective.
Mains plug of the charger is not (correctly)
plugged in.
Socket outlet, mains cable or charger is
defective.
Remedy
v Connect the battery to charger correctly.
v Clean the battery contacts (e. g. by con­
necting and disconnecting the battery
several times. Replace the battery if
necessary.
v Wait until the battery temperature is
between 0 °C and + 45 °C again.
v Replace the battery.
v Insert the mains plug into the mains socket
(completely).
v Check the mains voltage. Let the charger
be checked if necessary by an authorised
specialist dealer or the GARDENA Service.