The input of the power cable is located on the back of the heater. The exact position of
the cable on the wall is measured in relation to the heater mounting plate and has been
indicated in Figure 1.
Table 1.
A
4 in
DROP 4
100 mm
4.8 in
DROP 6
120 mm
5.5 in
DROP 7
140 mm
5.9 in
DROP 9
150 mm
B
A
Figure 1. Positioning of the heater
Installing an electric heater inside the sauna bench
HUUM DROP electric heater can also be partially mounted inside the sauna bench or
sauna floor.
• At least 14.8 in (375 mm) of the submerged heater should protrude from the
sauna bench surface;
• To cover the edges of the immersion hole use the embedding flange of
HUUM DROP electric heater.
The embedding flange of HUUM DROP electric heater is an accessory that you can
request from your HUUM product distributor. A user manual for the embedding flange is
provided with the product.
B
C
23.3 in
17.1 in
590 mm
435 mm
24.8 in
17.9 in
630 mm
455 mm
26.4 in
18.7 in
670 mm
475 mm
27.2 in
19.1 in
690 mm
485 mm
Min. 47.3 " / 1200mm
A
A
Min. 4" /100mm
D
6.7 in
170 mm
7.5 in
190 mm
8.3 in
210 mm
8.7 in
220 mm
X
C
D
E
MIN gap
12.2 in
47.3 in
310 mm
1200 mm
12.2 in
47.3 in
310 mm
1200 mm
12.2 in
47.3 in
310 mm
1200 mm
12.2 in
47.3 in
310 mm
1200 mm
Y
6
6 X 40
9.5"/240
mm
2.6"/65
mm
5