Télécharger Imprimer la page

AKO 16526A V2 Guide Rapide page 32

Masquer les pouces Voir aussi pour 16526A V2:

Publicité

Inputs and outputs
AUX1 relay configuration: 0= Deactivated, 1= Compressor/Crankcase resist-
o00
ance, 2= Light, 3= Virtual control, 4= Alarm, 5= Door frame resistor,
6=Drainage resistor
AUX2 relay configuration: 0= Deactivated, 1= Alarm, 2= Light, 3= Virtual
o10
control, 4= Defrost 2nd evaporator, 5= Door frame resistor, 6= Equal solenoid
status, 7= Equal device status, 8=Drainage resistor
AUX3 relay configuration: 0= Deactivated, 1= Alarms, 2= Light,
o20
3= External AO controller ON/OFF, 4=Defrost 2nd evaporator,
5= Door frame resistor, 6=Drainage resistor
o30 Analogue output type (AO): 0= 4-20mA, 1= 0-10V
EP
Output to level 1
HACCP alarm
h1 HACCP alarm maximum temperature
Maximum permitted time for activation of the HACCP alarm (0=HACCP alarm
h2
deactivated)
EP
Output to level 1
Information (read-only)
InI Option chosen in the configuration wizard
Pd Pump down active? 0=No, 1=Yes
PU Program version
Pr
Program revision
PSr Program subrevision
bU Bootloader version
br Bootloader revision
bSr Bootloader subrevision
PAr Parameter map revision
EP
Output to level 1
* According to the set-up wizard.
Description
Description
Description
32
1652H6A41 Ed. 04
Values Min. Def. Max.
0
*
6
0
2
8
0
0
6
0
0
1
Values Min. Def. Max.
ºC/ºF
-50 99.0 99.0
h.
0
0
255
Values Min. Def. Max.

Publicité

loading

Ce manuel est également adapté pour:

16526an v2