TROUBLESHOOTING - cont'd.
Test I, Runs But Does Not Cool Properly
www.norcold.com
Remove refrigerator from enclosure,
but keep DC power supply connected.
Inspect condenser coil for restriction.
YES
Is it
restricted?
NO
Check for 12 VDC at terminal (+) on
the control module.
YES
Is voltage
correct?
NO
Replace control module.
Remove restriction. Clean as needed.
Fan has failed. Replace refrigerator.
21
SERVICE MANUAL