TROUBLESHOOTING - cont'd.
Test B, Fan Over Current Cut-Out
www.norcold.com
Remove refrigerator from enclosure,
but keep DC power supply connected.
With freezer and fresh food
compartments at temperature
setting "5", make sure that the
exterior cooling fan is operating.
YES
Is the fan
operating?
NO
Measure DC voltage at control
module terminal "+".
YES
VDC
10.4 - 15.4?
NO
Replace the refrigerator.
Fan has failed. Replace the fan.
Replace control module.
13