WARNING
Electrical Shock Hazard
Electrically ground range.
Failure to do so can result in death, fire, or
electrical shock.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate and wire gauge are in accordance
with local codes.
Be sure that the electrical connection and wire size are adequate
and in conformance with CSA Standard C22.1, Canadian
Electrical Code, Part 1 - latest edition, and all local codes and
ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA

Electrical Requirements - Canada Only

Check with a qualified electrical installer if you are not sure
the range is properly grounded.
Range Rating*
120/240 Volts
120/208 Volts
8.8 - 16.5 KW
7.8 - 12.5 KW
16.6 - 22.5 KW
12.6 - 18.5 KW
*The NEC calculated load is less than the total connected load
listed on the model/serial number rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with
kit. For 50-amp rated cord kits, use kits that specify use with a
nominal 1³⁄₈" (34.9 mm) diameter connection opening.
A circuit breaker is recommended.
This range is equipped with a CSA International Certified
Power Cord intended to be plugged into a standard 14-50R
wall receptacle. Be sure the wall receptacle is within reach of
range's final location.
Do not use an extension cord.
The tech sheet and wiring diagram are located on the back of
the range in a plastic bag.
Specified Rating of
Power Supply Cord Kit
and Circuit Protection
Amps
40 or 50**
50
7