3
Remove Push Button: Rotate the push button (40) anti-clockwise to remove it from
the flush valve body
4
Place Cistern Cover: Place the cistern cover (10) onto the cistern Screw the push
button (40) clockwise into the hole on the top of the cistern cover
07.7 Flush Valve Adjustments (Optional)
☛
NOTE:
»
This chapter provides optional instructions for adjusting the flush valve body These
adjustments may not be necessary as the flush valve body arrives pre-adjusted to fit the
cistern (11) If adjustments are needed, follow the steps below:
1
Open Folded Locks: Use a flat-head screwdriver to pry open the folded locks (43) on
either side of the flush valve body
26
2
Release Pendulum Rod: Press the buckle (42) to detach the pendulum rod (41) from
the overflow pipe (52)
3
Set Scale: With one hand, press and hold the pins (44) on both sides of the flush valve
body With the other hand, adjust the scale to point at the desired number marking
Adjust Overflow Pipe: Lift up the overflow pipe (52) to match the same number
4
marking as on the scale
5
| EN |
5