23. Troubleshooting

Fault
Water does not flow
Water flows continu-
ously
Water volume too low
Flow time too short or
too long
Water too hot
Water too cold
If you cannot rectify a fault or if it is not in the list, please contact our customer
service department!

24. Spare parts

Description
1 Pressure cap . . . . . . . . . . . . . . . . 2000104775
2 Functional element . . . . . . . . . . . . 2000104352
3 Stop ring . . . . . . . . . . . . . . . . . . . . 2000104837
4 Push-on rosette . . . . . . . . . . . . . . 2000104809
5 Shower head spares kit . . . . . . . . 2000104849
6 Flow rate regulator
0.15 l/s . . . . . . . . . . . . . . . . . . 2000104782
0.20 l/s . . . . . . . . . . . . . . . . . . 2000104783
7 Lockable
Water volume regulator . . . . . . . . 2000104885
12
Cause
– Water volume regulator closed
– Functional element faulty
– Functional element faulty
– Shower head blocked with scale
– Supply pressure too low
– Dirty filter/non-return valve
– Water volume regulator not fully
open
– Incorrect setting
– Dirty filter
– Shower head blocked with scale
– Functional element faulty
– Temperature limit set incorrectly or
not set
– Cold water supply cut off
– Filter/non-return valve in cold-water
connection faulty
– Filter/non-return valve in hot-water
connection faulty
– Hot water flow blocked
Order No.
Description
8 Mounting kit consisting of:
Filters
Non-return valve
O rings
Seals
Locking rings. . . . . . . . . . . . . . .2000104777
Spares kit for functional element
Rubber parts
Compression spring
Locking ring
Sealing plug
Grub screw . . . . . . . . . . . . . . . . 2000104785
Remedy
➯ Restore it
➯ Replace it
➯ Replace it
➯ Clean it
➯ Check it
➯ Clean it
➯ Open it
➯ Set it
➯ Clean it
➯ Clean it
➯ Replace it
➯ Set it
➯ Open it
➯ Replace it
➯ Replace it
➯ Open it
Order No.