Troubleshooting
Problem
The appliance is
not working
The appliance is
on, but the
temperature is too
high/low
The appliance
produces an
unusually high
level of noise
The appliance is
leaking water
E- Supply 230V 50-60Hz
F- Condenser fan
G- Compressor
H- Evaporator fan
I-
Overload protector
Possible cause
1. The unit is not switched on
2. The plug and lead are damaged
3. The fuse in the plug has blown
4. Power supply issues
5. Internal wiring fault
1. Too much ice on the evaporator
2. Condenser blocked with dust
3. Doors are not shut properly
4. Appliance is located near a heat
source or airflow to the condenser
is being interrupted
5. The ambient temperature is too high
6. Unsuitable foodstuffs are being
stored in the appliance
7. Appliance is overloaded
1. Loose nut/screw
2. The appliance has not been
installed in a level or stable position
1. The appliance is not properly leveled
2. The discharge outlet is blocked
3. The movement of water to the
drain is obstructed
4. The water container is damaged
5. The drip tray is overflowing
EN
1. Check if the unit is plugged in
correctly and switched on
2. Call your agent or a qualified
technician for an inspection
3. Replace the fuse (UK plug)
4. Check the power supply
5. Call your agent or a qualified
technician for an inspection
1. Defrost the appliance
2. Call your agent or a qualified
technician for an inspection
3. Check the doors are shut, and
the seals are not damaged
4. Move the refrigerator to a more
suitable location
5. Increase ventilation or move
the appliance to a cooler
6. Remove any excessive hot
foodstuffs or blockages to the fan
7. Reduce the amount of food
stored in the appliance
1. Check and tighten all nuts and
screws
2. Check the installation position
and change it if necessary
1. Adjust the screw feet to level the
appliance (if applicable)
2. Clear the discharge outlet
3. Clear the floor of the appliance (if
applicable)
4. Call your agent or a qualified technician
for an inspection
5. Empty the drip tray with a sponge
Solution