Troubleshooting
Product part
Phenomenon
or function
Complete
machine
Rear wash
/ Front wash
Low heating
Warm air
drying
Half-way stop
Seat ring
Insufficient seat
ring temperature
heating
Deodorization
Remote
control
18
Whether the power supply is off
Not working
Whether the leakage protector is off
Power failure or not
Whether the water supply switch
is on
Whether the water supply is cut off
Not working
Whether the nozzle is blocked by
foreign matters
No skin contact with seat sensor
Is the water pressure gear set to
low gear
Low water
pressure
Whether the water supply channel
is normal
Water
Whether the water temperature is
temperature
set to low gear
is low
Whether the automatic stop time is
exceeded
Stop water
halfway
No skin contact with seat sensor
Whether the wind temperature gear
temperature
is set to low gear
Whether the automatic stop time is
exceeded
No skin contact with seat sensor
Is the seat temperature gear set to
low gear
Not working
No skin contact with seat sensor
Objects cover the sensing window
Incorrect use angle and sensing
No reaction
distance
Batteries run out
Cause
Power on
Press the leakage switch again
Wait for power supply
Turn on the water supply switch
Wait for water supply to recover
Remove foreign matters and manually
clean the nozzle
Re-adjust sitting position to ensure skin
contact with sensor
Reset the water pressure gear
Clean the filter screen at the water
supply outlet and supply water again
Reset the water temperature gear
Re-execute the function
Re-adjust sitting position to ensure skin
contact with sensor
Reset the water temperature gear
Re-execute the function
Re-adjust sitting position to ensure skin
contact with sensor
Reset the seat temperature gear
Re-adjust sitting position to ensure skin
contact with sensor
Remove the objects
Adjust angle and distance
Replace with new batteries
Solutions