Télécharger Imprimer la page

Generac GP Serie Manuel De L'utilisateur page 14

Masquer les pouces Voir aussi pour GP Serie:

Publicité

2. Unplugbattery chargerfrom wall outlet and control paneljack
when generatoris going to be in use.
NOTE:
Do not use the battery charger for more than 48 hours at one
charge.
Figure 15 - BatteryCharger Jack
BATTERY
CHARGER
iNPUT
3.1 PERFORMING
SCHEDULED
MAINTENANCE
It is important to perform service as specified in the Maintenance
Schedulefor proper generator operation, and to ensure that the
generatorcomplies with the applicableemission standardsfor the
durationof its useful life. Serviceand repairsmay be performed by
any capable personor repair shop. Additionally,emissions critical
maintenance must be performed as scheduled in order for the
Emissions Warranty to be valid. Emissions critical maintenance
consists of servicing the air filter and spark plugs in accordance
with the MaintenanceSchedule.
3.2 MAINTENANCE SCHEDULE
Follow the calendar intervals. More frequent service is required
when operatingin adverseconditions noted below.
CheckOil Level
ChangeOil $
CheckValveClearance
Service Air Filter
ReplaceSpark Plug
At EachUse
*Every 100 hours or Every Season
***Every Season
** Every 20 hours
Every Season
:i: Changeoil after first 30 hours of operation then every season.
*
Changeoil and oil filter every monthwhen operating under heavyload or in high
temperatures.
** Clean more often under dirty or dusty operating conditions. Replaceair filter
parts if they cannot be adequately cleaned.
***
Check valve clearance and adjust if necessary after first 50 hours of
operation and every 1O0 hoursthereafter.
3.3 PRODUCT SPECIFiCATiONS
3.3.1 GENERATOR S PECIFICATIONS
RatedPower............................................................... 5.5/6.5/7.5 kW**
SurgePower............................................................... 6.88/8.0/9.38 kW
RatedAC Voltage...................................................................... 120/240
RatedAC Load
Current@ 240V (5.5/6.5/7.5 kW) ..................22.9/27.1/31.3 Amps**
Current@ 120V (5.5/6.5/7.5 kW) ..................45.8/54.2/62.5 Amps**
RatedFrequency.................................................... 60 Hz @ 3600 RPM
Phase................................................................................ SinglePhase
** Maximum wattage andcurrent a resubject t o, andlimitedby,suchfactors
asfuel Btucontent, a mbient t emperature, altitude, e ngine condition, etc..
Maximum powerdecreases a bout 3 .5%for each1,000feetabove sealevel;
andwill alsodecrease a bout1%for each6° C (10° F)above16° C (60° F)
ambient t emperature.
3.3.2 ENGINESPECIFICAtiONS
5.5/&5kW
Displacement ..............................................................................
389 cc
SparkPlugType/Part No............................ NHSP LDF7TC/OG84420101
SparkPlugGap ............................. 0.028-0.031 inchor (0.70-0.80mm)
Gasoline Capacity . ........................................................
7.2 U.S.gallons
OilType .................. S eeChartin "BeforeStarting theGenerator" Section
OilCapacity ....................................................................
1 L (1.06Qts.)
RunTimeat 50%Load(5.0/5.5/6.5 kW).................................. 10 Hours
7.5kW
Displacement . .............................................................................. 420cc
Spark Plug Type/PartNo............................ NHSPLDF7TC/OG84420101
Spark Plug Gap............................................... 0.030 inch or (0.76 mm)
GasolineCapacity............................................................ 8 U.S. gallons
Oil Type .................................... SeeChart in "Adding EngineOil" Section
Oil Capacity .......................................................... 1.0 Liters (1.06 Qts.)
RunTime (50% Load).............................................................. 12 Hours
Class II EmissionCertified
3.3.3 EMISSIONSINFORMAtiON
The Environmental P rotectionAgency (and CaliforniaAir Resource
Board for generators certified to CA standards) require(s) that
this generator comply with exhaust and evaporative emission
standards. Locate the emissions compliance decal on the engine
to determine what standardsthe generatormeets. This generator
is certified to operate on gasoline. The emission control system
includes the following components (if equipped):
Air Induction System
• Ignition System
Intake Pipe/ Manifold
-
Spark Plug
Air Cleaner
_
Ignition Module
Fuel System
• Exhaust System
Carburetor
_
ExhaustManifold
FuelTank/Cap
-
Muffler
FuelLines
_
PulsedAirValve
EvaporativeVent Lines
_
Catalyst
CarbonCanister
12

Publicité