Télécharger Imprimer la page

Publicité

Liens rapides

Manual
Manuale / Manuel / Betriebsanleitung / Manual / Navodila / Priručnik / Uputstvo / Használati utasítás / Instrukcja
ZNO2059800 A
FlexiTech Exit Ceiling 20M/30M ATL
L
x 4
1
0 V
a
2
a
b
06/2023
20M
H
141mm
L
229mm
W
40mm
170 mm
W
x 1
x 1
x 2
c
30M
Maintained
198mm
+ 45°C
325mm
45mm
0°C
(35°C max. for 10 years lifetime)
PZ0
2,5 mm
x 2
b
d
2
1
A
Non Maintained
+ 45°C
+ 5°C
x2
Ø 5 mm
B
24h

Publicité

loading

Sommaire des Matières pour Eaton FlexiTech Exit Ceiling 20M ATL

  • Page 1 Manual Manuale / Manuel / Betriebsanleitung / Manual / Navodila / Priručnik / Uputstvo / Használati utasítás / Instrukcja ZNO2059800 A 06/2023 FlexiTech Exit Ceiling 20M/30M ATL Maintained Non Maintained 141mm 198mm + 45°C + 45°C 229mm 325mm 40mm 45mm 0°C + 5°C 170 mm...
  • Page 2 0,5 < S < 2,5 mm² Check the temperature range Non maintained on the 1st page for M and NM Maintained versions. Date installation Installation date /yyyy Installationsdatum T/ M/ FLEXITECH EXIT CEILING ATL ZNO2059800 A 06/2023 www.eaton.com Data installazione...
  • Page 3 DURATION TEST OCCURENCE CONFIGURATION Even Duration Test Day D Duration Test Day postponed by 7 days Disconnect the battery, wait for 10 seconds, and reconnect it if you decide to change configuration. FLEXITECH EXIT CEILING ATL ZNO2059800 A 06/2023 www.eaton.com...
  • Page 4 10 wks Battery Yellow 0,5 s. Constant Blinking DOUBLE-SIDE OR SINGLE-SIDE CONFIGURATION DOUBLE-SIDE SINGLE-SIDE LIGHTING LIGHTING Disconnect the battery, wait for 10 seconds, and reconnect it if you decide to change configuration. FLEXITECH EXIT CEILING ATL ZNO2059800 A 06/2023 www.eaton.com...
  • Page 5 SINGLE-SIDE DOUBLE-SIDE 60lm 110lm 120lm 210lm xx lm 60lm 95lm 120lm 190lm 55lm 65lm 120lm 125lm 20lm 20lm 40lm 45lm PICTOGRAMS CONFIGURATION CLICK DOUBLE-SIDE ONLY FLEXITECH EXIT CEILING ATL ZNO2059800 A 06/2023 www.eaton.com...
  • Page 6 ON BOTH SIDES CLICK x6 CLICK CLICK 230 V...
  • Page 7 WEEE : Contacter votre revendeur local Route de la Longeraie 7 ZNO2059800 A - 06/2023 Eaton.com/recycling 1110 Morges, Switzerland Eaton.eu Eaton is a registered trademark. © 2023 Eaton All trademarks are property 100 % All Rights Reserved of their respective owners.
  • Page 8 Non maintained Maintained Maintained Duration test & Duration test Check the tempera- Before Battery luminous flux configu- occurence ture range on the 1st Installation date ration configuration maintained page for M and NM versions. Non maintenu Maintenu Durée des tests et Maintenu Avant Batterie...
  • Page 9 Disconnect the battery, Autotest LED Description wait for 10 seconds, - Charge / Lamp / - Green / Yellow and reconnect it if Double-side or Single-side configuration Battery - Constant / you decide to change - 1wk / 10wks Blinking configuration.
  • Page 10 Replaceable Magnet Test Not replaceable Hold the magnet Functional Test Battery pack, Order code against the product Duration Test Pictogram configuation If the battery duration is insufficient, replace the Reset luminaire to select light level battery. DIM level (in Mains mode). When the life time of light source is over, replace Green / Yellow the luminaire.

Ce manuel est également adapté pour:

Flexitech exit ceiling 30m atl