5. See
Figure
3-4. Move engine choke lever
to the RUN position (choke lever to the
right).
6. Press and hold STOP/RUN/START switch
in the START position. When engine
starts, release the switch to the RUN posi-
tion.
Generator Shut Down
Equipment and property damage. Disconnect
electrical loads prior to starting or stopping unit.
Failure to do so could result in equipment and
property damage.
1. Shut off all loads and unplug electrical
loads from generator panel receptacles.
2. Let engine run at no-load for several min-
utes to stabilize internal temperatures of
engine and generator.
3. See
Figure 3-2
for LP. Close fuel valve and allow unit to
run until the fuel in the carburetor is used
up.
4. Move STOP/RUN/START switch to STOP.
NOTE: Under normal conditions, close the
appropriate fuel valve and allow generator to
run carburetor bowl out of fuel. For emergen-
cies, switch to STOP.
Low Oil Level Shutdown System
The engine is equipped with a low oil level
sensor to shut down the engine automatically
when the oil level drops below a specified
level. The engine will not run until the oil has
been filled to the proper level.
IMPORTANT NOTE: Verify proper engine oil
and fuel levels before use.
Charging the Battery (electric
start units only)
Explosion. Batteries emit explosive gases while
charging. Keep fire and spark away. Wear protective
gear when working with batteries. Failure to do so
could result in death or serious injury.
Risk of burns. Batteries contain sulfuric acid and can
cause severe chemical burns. Wear protective gear
when working with batteries. Failure to do so could
result in death or serious injury.
Battery Recycling
Always recycle batteries in accordance with
local laws and regulations. Contact your local
solid waste collection site or recycling facility
to obtain information on local recycling pro-
18
CAUTION
for gasoline or
Figure 3-5
WARNING
WARNING
cesses. For more information on battery recy-
cling, visit the Battery Council International
website at: http://batterycouncil.org
NOTE: The battery shipped with the generator
has been fully charged. A battery may lose
some of its charge when not in use for pro-
longed periods of time. If the battery is unable
to crank the engine, plug in the 12V charger
included in the accessory box. RUNNING
THE GENERATOR DOES NOT CHARGE
THE BATTERY.
Use battery charger plug to keep the battery
charged and ready for use. Battery charging
should be done in a dry location.
(000136)
1. See
Charger Input jack, located on the control
panel. Plug wall receptacle end of battery
charger into 120 Volt AC wall outlet.
2. Unplug battery charger from wall outlet
and control panel jack when generator is
to be in use.
Figure 3-6. Battery Charger Input Jack
(000137a)
(000138a)
3-6. Plug charger into Battery
Figure
BATTERY
CHARGER
INPUT
Owner's Manual for Portable Generator