9. Troubleshooting guide
Fault
Motor does not start
Engine performance
drops
Imprecise scarifying
result
Motor is running,
roller is not
rotating
Important notice! To protect the motor itis equipped with a thermal overload switch which cuts
out when overloaded and starts again automatically after a short cooling-down period.
Anl_PE_EV_1231_SPK7.indb 92
Anl_PE_EV_1231_SPK7.indb 92
GB
Possible causes
a) No electricity in plug
b) Cable defective
c) Switch, switch/plug block
defective
d) Connections to motor or
capacitor disconnected
e) Housing clogged
a) Soil is too fi rm
b) Housing clogged
c) Roller badly worn
a) roller worn
b) Wrong working depth
a) Toothed belt is torn
- 92 -
Rectifi cation
a) Check line and fuse
b) Check
c) Have machine checked by a
customer service center
d) Have machine checked by a
customer service center
e) If necessary adjust working depth.
Clean housing so that the roller can
run freely
a) Change working depth
b) Clean housing
c) Replace roller
a) Replace roller
b) Correct working depth
a) By customer service workshop