- North America: 15 A protection;
- Rest of the world: 16 A protection.
For machines equipped with a variable speed
drive, it is imperative that they be connected
to a junction box on a circuit fitted with a
300 mA RCD.
Note: Any problem resulting from any other
type of connection will not be covered under
warranty.
Before connecting your machine to the mains
supply and in order to prevent the motor from
burning out when it is switched on, it is
important to check that the mains supply
matches the machine specification (see
machine nameplate).
This machine complies with Machinery
Directives 2006/42, 2006/95, 2004/108 and is CE marked as proof of this.
Please familiarise yourself with the safety pictograms displayed on the machine:
This pictogram indicates a cut hazard. You will find it at the front of the machine
around the loaf positioning area (fig.10, n°20).
You will find the circuit diagram for the machine on the back of the electrical
enclosure door (fig.10, n°22).
This pictogram indicates an electrocution hazard. Please isolate the machine
before carrying out any work on it. You will find it at the back of the machine close
to the power cable and inside the machine on the electrical enclosure (fig.10,
n°21).
5.4
Commissioning:
Before commissioning, ensure that there are no extraneous objects interfering with the machine's
moving parts.
For machine operation, please refer to the "Operation" chapter.
5.5
Danger:
If the user or the machine is in danger, you must use the main isolator switch to cut the power supply
to the machine.
Remove the plug from the power socket before any maintenance and/or servicing work.
Do not touch the blade, even if it is stationary.
To replace the blade, have the work done by your approved dealer.